background image

MOUNTING INSTRUCTION 

 

The  diameter  of  the  cable/spindle 
hole  should  be  minimum  9  mm, 
maximum  12  mm.  The  hole  must 
be de-burred well to avoid damage 
to the cable.

Mount Rotating Premier Dial Ring Bearing 
to the safe door with the mounting 
adapters. Tighten with screwdriver.  
Mount the lock on the inside of the safe 
door with supplied mounting screws 
leaving them a little bit loose. See EM35-
xx Technical Manuals for lock details.

Insert the shaft through the center hole of 
the Dial Ring Bearing until it stops on lock 
cam. Mark the shaft at the front surface of 
the Dial Ring Bearing. Pull out the shaft 
and measure an additional 1/4”(6.35mm) 
longer from the shaft mark. Cut shaft and 
remove sharp edges.

Put the spindle into Premier back plate and route the cable into the spindle 
groove. Insert the cable and shaft into the center hole of the Dial Ring Bearing 
and guide the cable through the hole in the lock body. Align input holes to the 
mounting adapters so that the input is flush with the safe door.

Turn input clockwise until it snaps into 
place. Place 9V alkaline battery (Duracell 
TM) into the bottom compartment of the 
input and close the compartment door. 

Tighten lock mounting screws.

Insert the connector of the entry unit in 
the outer position.  Check that the 
connector is completely seated. To tie the 
cable, push it into the square groove in 
the lock cover.

Enter the preset combination 
(1-2-3-4-5-6) and turn input to the RIGHT 
within 3 seconds to open the lock. (You 
must turn the input back to the left to 
lock.)

!

!

!

!

!

 

Installation Instructions 061516 

Page 1 of 1 

Step 1. Mount Rotating Premier Dial Ring Bearing to the safe door with the mounting adapters. Tighten with 

screwdriver. 
Step 2. Using the mounting screws, mount the lock in the correct position on the inside of the safe door.  

Tighten the screws. 
Step 3. Insert the shaft through the center hole of the Rotating Premier Dial Ring Bearing until it stops on 

lock cam. Mark the shaft at the front surface of the Rotating Premier Dial Ring Bearing. Pull out the shaft and 

measure an additional 1/4”(6.35mm) longer from the shaft mark. Cut shaft and remove sharp edges. 

 

Step 4. Put the Premier Input onto the shaft. Insert the battery cable and shaft into the center hole of Rotat-

ing Premier Dial Ring Bearing. Align input holes to the mounting adapters so that the input is flush with the 

safe door.  

Step 6 

Step 7 

Step 5 

Step 3 

Step 2 

Step 5. Turn input clockwise until it snaps into place.   

Step 6. Place 9V alkaline battery (Duracell ™) into the bottom compartment of the input and close the com-

partment door. 
Step 7. Enter the preset combination (1-2-3-4-5-6) and turn input to the RIGHT within 3 seconds to open the 

lock. (You must turn the input back to the left to lock.) 
To remove input from safe door, first remove the battery. Then, using a small screwdriver, press and hold 

down the tab (marked red in the picture shown above) from the inside of the battery compartment. While 

holding down the tab, turn the input counter clockwise until it stops and pull off. (Be careful not to pull too 

far because the input cable is still connected. 

®

 

Lock Technology

 

Rotating Premier Input Installation Instructions 

Step 1 

Step 4 

To Remove 

!

!

PI30•x1 Technical Manual rev. 160610 

 

 

 

© 2016 Lock Technology  Page 

!

 of 

!

 

2

2

Отзывы: