Instruction Manual
NivuFlow 650
page 36
NF 650 - rev. 01 / 29.06.2020
DANGER
Danger from electrical current
Multiple wire cables (strands) of the AC power supply circuit as well as of relay connections
shall be equipped with ferrules featuring an isolated protective collar (plastic ferrule) to avoid
danger due to several protruding wires.
Non-observance may result in personal injuries.
Tension clamp terminal block
Power
supply
Bus/
Network
Terminals O/I
etc.
Wire cross-section,
rigid cables in [mm²]
0.2...2.5
0.2...0.5
0.14...1.5
Wire cross-section,
flexible cable in [mm²]
DC only:
0.2...2.5
0.2...0.5
0.14...1.5
Wire cross-section (flexible) with ferru
-
le blank in [mm²]
DC only:
0.25...2.5
0.25...0.5
0.25...1.5
Wire cross-section (flexible) with ferru
-
le with plastic sleeve in [mm²]
0.25...2.5
Undefined
0.25...0.5
Table 21-1 Wire cross-section
The measurement transmitter NivuFlow 650 is available in different
Types
:
• Type T2
• Type TR
• Type T4
• Type TM
• Type TZ
F
c
See also Sect. “17.1 Device Types”
All types have identical terminal designations. These blocks are functionally assigned to the
different connection areas. Types T4, TM and TZ have additional terminal blocks.