background image

 

To set the incline in X axis press                      - each time you press the buttons the laser plane  
will incline in the X axis  
 
 
To set the incline in X axis press                       - each time you press the buttons the laser plane  
will incline in the X axis.  

 
ADS System 
 

Enable  this  system  will  cause  the  LED  will  blink  slowly.  After  automatic  levelling  of  the 
instrument,  after  about  3  seconds,  the  ADS  function  is  activated.  Excessive  inclination  of  the 
instrument  or  unwanted  movement  /  strike  will  cause  the  LED  will  blink  quickly  -  warning  the 
user about disheveling.  

 
PRINCIPLE OF OPERATION  
 
 
 
Height Measurement

  

  
Turn the power on to Level the instrument itself. Once leveled, the laser head 
starts to spin, setting the laser plane. Attach the laser sensor on the laser staff. 
Place a laser staff with attached sensor on a benchmark (zero point)- reset  the 
position  of  sensor  (adjust  the  height  of  the  sensor  to  define  a  zero  level,  the 
laser staff should also indicate zero). Move the laser staff with sensor to another 
point which height you want to measure, adjust the height of the sensor to place 
it  in  the  field  of  the  laser  beam  -  move  it  up  or  down  on  the  laser  staff.  The 
difference of sensor positions on the staff will indicate the height differences of 
the measured point compared to the benchmark.  
 
 

Slope determination 
 

Set the laser level on a tripod. Set the laser level in the axis you want to tilt and 
turn on the laser level. The laser plummet (bottom) indicates the first point of the 
axis, on the other end point set the laser staff with laser sensor - reset position 
(sensor  and  staff).  Depending  on  the  desired  value  of  inclination  slide  the 
sensor on a staff and by remote control change the inclination of the laser plane 
in  order  to  fit  in  the  position  of  the  laser  sensor  (this  shift  of  laser  sensor  will 
specify the inclination, eg. If you want to get a inclination of 1%, at a distance of 
10 m (laser staff) the difference between the height of the zero point on the staff 
should and designated inclination should be 10 cm).    
 

Working with the vertical plane

  

 
NL500 / NL500G can set horizontal or vertical beam. If you work with a vertical laser beam 
you must set the laser level as in the picture beside. After switching on the laser level the 
device will level by itself – the head will start to rotate - setting a vertical plane.  
The laser plummet (top) defines a line perpendicular to the plane of the laser level, which 
is used in all perpendicular  works (building partitions, setting 90° angle, etc.).  

 
 
 

Содержание NL500

Страница 1: ...NL500G Thank you for purchasing a Nivel System NL500 NL500G laser level To best use the purchased instrument please read the instructions carefully and put in a convenient spot so that in the future y...

Страница 2: ...2 WARNING The device contains a rechargeable nickel hydrogen batteries which must be recycled and should be disposed in accordance with the requirements WEEE Reg DE23874031...

Страница 3: ...to it it s possible to stop the beam at a given distance NL500 NL500G models can be controlled from the device control panel or remotely with remote control Laser level is waterproof and can be used o...

Страница 4: ...lean water and consult a doctor Broken or damaged transport box or transport box latches can lead to falling out of the box and damage the laser The collapse of laser level to the ground can lead to d...

Страница 5: ...protect from moisture Never put a wet instrument to the transport box wait until dry CONTROL PANEL 10 11 8 6 9 5 7 4 1 2 3 12 Description of buttons and functions 1 ON OFF switch Turns the device on a...

Страница 6: ...On the front panel press The instrument will level by itself and the power LED lights up Press the button again to turn off the power Once leveled up the laser LED stops blinking and the laser head r...

Страница 7: ...The difference of sensor positions on the staff will indicate the height differences of the measured point compared to the benchmark Slope determination Set the laser level on a tripod Set the laser...

Страница 8: ...e the instrument 180 WARNING Be careful not to move the instrument while the head is spinning 5 Turn on the instrument once again and wait until it level automatically 6 Once again mark the position o...

Страница 9: ...the markers 9 If the distance between the markers is less than 3mm calibration is not necesery LASER SENSORS Nivel System RD100 Precise mode Coarse mode Too high the laser signal is below please Lowe...

Страница 10: ...L 76 W 35 H mm Net Weight 373g with battery Features Easily set up adjust the balance with magnets and vials at both side and top with LCD at both front and back easier for mounting and detecting the...

Страница 11: ...r is switched with loudest sound sequence of the switch is loudest no sound normal sound Accuracy switch Detector is switched with highest accuracy sequence of the switch is highest accuracy middle ac...

Страница 12: ...sensor digital option NL BR laser bracket Tripod adapter 0 90 Rechargeable battery pack CH 1 charger YR laser shelf TR R TR G laer targets GL R GL G laser glasses Laser case Remote controller SJJ1 tri...

Страница 13: ...n of surveying equipment shall not be considered a warranty repair The user shall be charged for unjustified complaints in accordance with the effective price lists Warranty repairs shall be carried o...

Страница 14: ...0 C 50 C Power DC 4 8 6 V 4 rechargeable batteries type D NiMH Working time about 30h Battery charging time about 7h Dust and waterproof IP56 Dimensions 206 x 206 x 211 mm Weight 2 8kg Remote control...

Страница 15: ...i kujemy za zakupienie niwelatora laserowego firmy Nivel System model NL500 NL500G Aby m c jak najlepiej wykorzysta zakupiony instrument prosimy uwa nie przeczyta instrukcj i po o y w dogodnym miejscu...

Страница 16: ...16 UWAGA Urz dzenie zawiera baterie niklowo wodorowe baterie te musz by poddane recyklingowi lub powinny by utylizowane zgodnie z wymogami WEEE Reg DE23874031...

Страница 17: ...zyzn laserow dodatkowo urz dzenia wyznaczaj o p aszczyzny laserowej laser liniowy punkt do g ry i punkt do do u Za pomoc laser w mo liwe jest tak e rysowanie linii laserem funkcja skanowania dzi ki cz...

Страница 18: ...wynikaj ce z tego powodu straty Niew a ciwe u ycie lasera oraz stosowanie go niezgodnie z opisanymi w tej instrukcji procedurami mo e spowodowa obra enia lub nara enie si na nadmiern dawk promieniowan...

Страница 19: ...niew a ciwymi ruchami lub reakcjami na skutek czenia z innymi produktami BATERIE W NL500 500G zastosowano akumulatorki niklowo wodorowe kt re mog by adowane adowanie akumulatork w odbywa si za po redn...

Страница 20: ...k w aby wprowadzi spadek w kierunku osi Y 11 Dostosowanie spadku w kierunku osi X kiedy niwelator prze czony jest w tryb r czny u yj przycisk w aby wprowadzi spadek w kierunku osi X 12 System ADS kied...

Страница 21: ...chni w osi X Aby ustawi spadek w osi Y naci nij odpowiednio przyciski ka dorazowe przyci ni cie spowoduje pochylanie si wyznaczanej przez laser powierzchni w osi Y System ADS W czenie funkcji spowoduj...

Страница 22: ...ak jak na obrazku obok Po w czeniu urz dzenie samo spoziomuje si g owica zacznie obraca si wyznaczaj c p aszczyzn pionow Pionownik laserowy g rny wyznacza lini prostopad do generowanej p aszczyzny las...

Страница 23: ...pomi dzy znaczkami z pierwszego i drugiego po o enia niwelatora je li odleg o jest mniejsza ni 6 mm kalibracja nie jest potrzebna w przeciwnym przypadku zalecany jest kontakt z serwisem 8 Wykonaj anal...

Страница 24: ...czna CZUJNIKI LASEROWE Nivel System RD100 Wy wietlacz Tryb precyzyjny Tryb zgrubny Za wysoko sygna laserowy znajduje si poni ej obni czujnik s yszalny b dzie d wi k wysokiej cz stotliwo ci Jeste na w...

Страница 25: ...dbioru lasera Zakres temperatury pracy 20 C 50 C Wymiary 170 L 76 W 35 H mm Waga z bateriami 373g wy wietlana jednostka strza ki nawigacyjne odchylenie od poziomu wi zki laserowej sygna d wi kowy prze...

Страница 26: ...lacza prze cznik g o no ci sygnalizatora poziomu prze cznik trybu dok adno ci pracy magnes y libelka znacznik poziomu Wska nik poziomu LED G rny wska nik LED czerwony wi zka laserowa znajduje si powy...

Страница 27: ...ie NL BR uchwyt czujnika Adapter na statyw 0 90 Komplet akumulatork w CH 1 adowarka YR p ka laserowa TR R TR G tarczki laserowe GL R GL G okulary laserowe Waliza transportowa Pilot zdalnego sterowania...

Страница 28: ...t u ytkownik zgodnie z obowi zuj cymi cenami Naprawa gwarancyjna dokonana b dzie wy cznie na podstawie dokumentu zakupu W ramach gwarancji Gwarant nie ponosi odpowiedzialno ci z tytu u skutk w usterek...

Страница 29: ...g owicy zmienna 0 60 120 300 600 obr min Skanowanie 0 10 45 90 180 Praca w zakresie temperatur 20 C 50 C Zasilanie DC 4 8 6 V 4 akumulatorki typ Ni MH Czas pracy ok 30 godz Czas adowania akumulatork w...

Страница 30: ...30 Notatki...

Страница 31: ...31...

Страница 32: ...32 Nivel System serwis i wsparcie TPI Sp z o o ul Bartycka 22 00 760 Warszawa Polska 48 22 651 03 06 48 22 651 03 09 tpi tpi com pl www nivelsystem com...

Отзывы: