![Nitty-Gritty Inox mark Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/nitty-gritty/inox-mark/inox-mark_manual_1696688028.webp)
25
5. INSTALLATION
5.1.
At the user’s care
The user must provide the following:
Installation area complying with the local standards in force concerning health and safety at work.
An electricity supply line complying with the standards in force in the place of installation.
An efficient grounding system..
A disconnecting switch with automatic protection against short-circuiting, discharges to earth and
dispersion between the supply line and the machine.
5.1.1. Lighting
The place where the machine is installed must feature sufficient lighting either natural and/or
artificial, and comply with the standards in force in the relevant country.
All areas must be equally lit. There must be no area of shadow likely to cause nuisance, no irritating
dazzle and no stroboscopic effects.
An average lighting of 300-500 lux/m is recommended.
5.1.2. Space requirements
Provide installation areas, which enable the machine to be easily accessed.
Once it has been installed, place the machine on a workbench near the pieces to mark.
The air flow around the equipment should never come less, since a
reduced air flow would cause overheating and even damage to the
internal components.
5.1.3. Electrical connections
Before providing the electrical connections, make sure the supply line upstream:
IMPORTANT
All connections to the mains must be made with this disconnected and by qualified and
explicitly authorized personnel in accordance to the standards in force.
Features an earth conductor;
Has a suitable size for the machine’s power requirements;
Features a device for protection against overcurrent due to overloading or short-circuits;
Features a circuit breaker suiting the kind of earthing system, for protection against indirect
contact.
Before using the INOX MARK, check the integrity of the insulation of cables, handgrip with graphite
insert, sockets and plugs composing the machine.
Isolating the electricity supply: interrupting the electricity supply, even for a short lapse of time, will
immediately interrupt machine operation. Once the supply is resumed, the machine starts
automatically and immediately..
5.2. Normal stop
Put the main switch in the position OFF in the front panel of the machine.