6
4-5. How To Operation
WARNING
●
Be sure to turn the switch OFF and remove
the power plug from power supply whenever
adjusting chamfering angle.
●
The workpieces should be fixed as much as
possible while working.
(1) Select the chamfering level.
(2) Make sure that the Switch is set at "OFF" position
and connect the power plug to the power supply.
(3) Hold the Housing up. Start the tool.
(4) Hold the Housing and Sub Handle firmly. Place
the circle plate on the top of part to be machined,
then slowly fit the Indexable Insert to the point to
be machined. Feed in the Indexable Insert turning
direction while tracing the side face using the
Guide Sleeve.
Chamfering
direction
Fig. 7
In case of chamfering stainless steel, chamfer deep
to the desired chamfering level by one span of
operation. Repeat of chamfering makes the life of
Indexable Insert shorter.
5.
HOW TO REPLACE INDEXABLE
INSERT AND GUIDE SLEEVE
WARNING
●
Always turn the Switch OFF and remove the
power plug from the power supply.
●
Bear in mind that Indexable Insert and holder are
much heated right after the operation.
5-1. How To Replace Indexable Insert
(1) Pull out the lever in the arrow direction to remove
the Lock Wire from the stopper, and the Circle
Plate will swing. (Fig.8)
Fig. 8
(2) Use the accessory Hex. Socket Screw key 5 to fix
the holder. (Fig.9)
Fig. 9
(3) Use the accessory Spanner T-15D to loosen the
Indexable Insert holding screw, and remove the
Indexable Insert. (Fig.10)
Fig. 10
(4) Set the new Indexable Insert (including the one
whose face is changed) while using care on the
Indexable Insert direction, and use the Spanner
T-15D to securely fasten the Indexable Insert
holding screw.
(5) Swing the Circle Plate, hang the Lock Wire on the
Stopper groove, and use the lever to lock it. (Fig.11)