background image

NITTAN (UK) LTD.

Hipley Street, Old Woking, Surrey, England, GU22 9LQ. UK

Tel:

+44 (0) 1483 769555 • 

Fax:

+44 (0) 1483 756686 

Web Site:

www.nittan.co.uk

• E-mail:

[email protected]

• Ref No: NISM/EV-DP/03

• Date: 16.04.09  • Issue: 3

• Evolution

• EV-DP

• 

Dual Wavelength photoelectric sensor instruction manual

EV-DP 

Analogue

Addressable Dual

Wavelength

Photoelectric 

Smoke Sensor

instruction manual

Quality System Certificate No. 041

Assessed to BS EN ISO 9001:2000

Содержание EV-DP

Страница 1: ...e www nittan co uk E mail sales nittan co uk Ref No NISM EV DP 03 Date 16 04 09 Issue 3 Evolution EV DP Dual Wavelength photoelectric sensor instruction manual EV DP Analogue Addressable Dual Waveleng...

Страница 2: ...EV UV are all elegantly designed low profile fire sensors which are aesthetically pleasing thus enabling them to blend unobtrusively into modern working environments The evolution analogue addressable...

Страница 3: ...ng terminals provide a switched current sink function which operates when the detector goes into alarm condition suitable for the operation of an auxiliary function such as a remote indicator Terminal...

Страница 4: ...ss must be set before the sensor is fitted into place Fit the plastic dust cover supplied over the sensor to keep out dust etc until the system is commissioned If the dust cover is not fitted and the...

Страница 5: ...l It may be advisable to ensure that such cleaning is conducted regularly in the future iv Ensure no equipment which may generate combustion products has been installed in the vicinity of the detector...

Страница 6: ...proceeding to the next sensor ensure that the sensor previously tested does not re operate due to the presence of residual smoke Functional Tests The functional test checks the sensor operation These...

Страница 7: ...ve Humidity of up to 95 measured at 50 C non condensing Section 8 EMC Installation The installation shall be in accordance with the regulations either of the approval body for an approved system or ot...

Страница 8: ...ncrement the address to be programmed by one 1 and prompt for the next sensor to be fitted If no detector is fitted the programmer will report No Unit Found Comm Error 1 Fit a new sensor and press OK...

Страница 9: ...olution EV DP analogue addressable photoelectric sensor instruction manual Auxiliary terminal RIL current limited to 3mA Base control is not current limited as the auxiliary equipment provides the lim...

Страница 10: ...ct your local city office or your household waste disposal service Section 13 ROHS COMPLIANCE STATEMENT RoHS compliant and lead free This product complies with the RoHS Restriction of Hazardous Substa...