Nitronic MiniStrip Скачать руководство пользователя страница 8

Sdasdasdsdfdsdcdscsdcdcd 
cdcsc 

 

8

Das Bild kann zurzeit nicht angezeigt werden.

Nitronic  AG 

Mattenstrasse 11 

 

CH – 2555 Brügg 

Tel.    +41 32 373 70 70 

Switzerland 

 

10 

  Unscrew the end cap 

(6)

 and carefully pull out the cover 

plate 

(7)

. The four stripping blades 

(8)

 will now be visible. 

(Fig. 11)

 

 
 
 
 
 
 
 
 

In  order  to  avoid  losing  the  very  small  stripping  blades, 
we recommend that you put down a dark-colored smooth 
mat  and  use  a  pair  of  tweezers.  All  four  stripping  blades 
must  be  changed  at  the  same  time  in  order  to  maintain  a 
consistent stripping quality 

 
 

  Remove each stripping blade 

(8)

 individually from the guide 

plate 

(9)

 

  If  necessary,  carefully  clean  the  guide  plate 

(9)

  with  a  dry 

brush

 

 

  Insert  new  stripping  blades 

(8)

  individually.  As  far  as 

possible, align the stripping blades with the track so that 
the blades do not subsequently jam. 

(Fig. 13)

 

 
 
 
 
 
 
 
 
 
 

 

 

Carefully replace the cover plate 

(7)

. The chamfer 

(10)

 

must point towards the outside. 

(Fig. 14) 

 
 
 

  Screw the end cap 

(6)

 back on again, but 

do not tighten

(Fig. 14)

 

 
 

 

 

 

 

 

 

 

 

 

Fig. 11 Removing cap and cover 

 

 

 

 

 

 

 

 

 

 

Fig 13.Insert blades 

Fig. 14 Assemble plate and cover 

 

 

 

 

 

 

 

10 

Содержание MiniStrip

Страница 1: ...it nicht angezeigt werden Nitronic AG Mattenstrasse 11 CH 2555 Br gg Tel 41 32 373 70 70 Switzerland MiniStrip Precision Stripping Tool Operating Instructions Edition V3 18 Please read through these O...

Страница 2: ...use damage to the tool or the cable This pictogram serves to illustrate work and operating procedures which must be adhered to as well as to give important information about how the tool works Table o...

Страница 3: ...s or fibers Precision blade diameter control with a micrometer scale allows a quick set up of diameter The locking screw of the diameter adjusting system makes the tool available even for military app...

Страница 4: ...ng diameter should be set as accurately as possible The stripping result would otherwise be unsatisfactory Blocking of the centering device with the blocking screw 16 white is not absolutely necessary...

Страница 5: ...diameters 0 5 mm which are to be stripped very short 3 mm the length setting ring gauge 2 should not be fixed in place so that when the stripping head 5 is pulled back the stripping blades can be ope...

Страница 6: ...ipped off by pulling harder This can damage the blades Check that the wire has been stripped with a clean cut and at the correct length Check and adjust the stripping diameter and stripping length as...

Страница 7: ...t require the application of grease or oil In order to ensure correct function and long service life avoid contaminating the tool with greasy or oily substances Cleaning The waste created by the strip...

Страница 8: ...ping blades must be changed at the same time in order to maintain a consistent stripping quality Remove each stripping blade 8 individually from the guide plate 9 If necessary carefully clean the guid...

Страница 9: ...ar as it will go and holding this position tighten the end cap 6 Fig 15 The Nitronic MiniStrip is now ready for use Changing the stripping blades with centering unit The stripping blades must only be...

Страница 10: ...ogether Fig 17 The centering device can now be removed as a complete module Fig 18 Remove each stripping blade 8 individually from the guide plate 9 If necessary carefully clean the guide plate 9 with...

Страница 11: ...ghten it Fig 21 Set diameter scale 4 to a diameter of 0 mm Slowly push the stripping head 5 back and forth Fig 22 This will cause the four stripping blades to automatically fit into the tracks on the...

Страница 12: ...y rotating the centering scale 17 fully open the centering jaws 25 and insert calibrating pin 30 Then by rotating the centering scale 17 close the centering jaws as far as the calibrating pin 30 Fig 2...

Страница 13: ...pped off Pull between grip and cable is too strong or too weak Apply consistent and constant pull during stripping Isolation does not strip off Diameter differential between isolation and wire is very...

Страница 14: ...m Stripping system Rotative 4 blades Dimensions Diameter 18mm Length 165mm Weight 90g Construction entirely metal construction Stripping blades HSS Titanium coated carbide optional Processable insulat...

Страница 15: ...1 Operating instructions EN 7110 1 Or short operating instructions 1 Headless blocking screw 1 Allen Key 1 Allen Key 1 Calibrating mandrel Replacement parts Quantit y Description Article Number 1 Set...

Отзывы: