eNBioAccess-T1 User Guide
18
(138-827) (Bangi-dong, Hyundai Topics Building) 4
th
Floor, Wiryeoseongdae-
ro, Songpa-gu, Seoul, Korea
Tel : 82-2-6488-3232 , Fax : 82-2-6488-3099,
E-Mail: [email protected]; http://www.nitgen.com
Card Format
The type of card to be used can be set.
Settings
Display Method
No Use
Do not use the card authentication
EM
Use a low-frequency (125KHz) EM card
MIFARE
Use a high-frequency (13.56MHz) MIFARE card
HID 26bit
Use a low-frequency (125KHz) HID 26 Bit card
HID 35Bit
Use a low-frequency (125KHz) HID 35 Bit card
HID 37Bit
Use a low-frequency (125KHz) HID 37 Bit card
iClass 26Bit
Use a HID iClass 26 Bit card
iClass 35Bit
Use a HID iClass 35 Bit card
iClass 37Bit
Use a HID iClass 37 Bit card
Wiegand Output
This mode is available if the terminal is equipped with a separate controller operated by Wiegand input.
Settings
Display Method
No Use
Do not use the Wiegand communication
26Bit
Perform the Wiegand communication by a format of 26Bit
34Bit
Perform the Wiegand communication by a format of 34Bit
Device Mode
If reader mode is selected, wiegand output is Card Number when authentication is Success.
If access control is selected, wiegand output is User’s ID when authentication is Success.
Sitecode
Set the value of Sitecode to transfer upon Wiegand output.
If Wiegand output is 26bit, a value of 0 to 255 can be set. If Wiegand output is 34Bit, a value of
0 to 32767 can be set.
Ext 485
Can select external RS 485 device.
If is select CP040, CP040 process authentication and lock control, log data.
485 ID
Can assign ID of External RS 485 device to 0-7.
1:N Level
When 1:N authentication, set the verification level to 5-9.
1:1 Level
When 1:1 authentication, set the verification level to 1-9.
Max ID Length
This indicates the length of ID which can be entered to the maximum.
Network Mode
Set whether the terminal is used to either a stand-alone mode or a network mode.