29
Protocol
PELCOD
The communication protocol is self detected and does not need setting up.
Baud Rate
2400 / 4800 / 9600 / Automatic Identify
The baud rate is automatically detected when dipswitch 9 and 10 are set to ON.
Otherwise the values are:
2400 baud rate Dipswitch 9 OFF - Dipswitch 10 OFF
4800 baud rate Dipswitch 9 ON - Dipswitch 10 OFF
9600 baud rate Dipswitch 9 OFF - Dipswitch 10 ON
Auto Detect
Dipswitch 9 ON - Dipswitch 10 ON
The default is set at 9 & 10 OFF which is 2400 bps.
Hard Address
This is the ID address of the PTZ camera set in the first 8 dipswitches located under the
plastic cover under the PTZ lens. The default is 1 i.e dipswitch 1 set to ON. Numbers are in
binary format so ID number value =
Dipswitch Number: 1 2 3 4 5 6 7 8
Value: 1 2 4 8 16 32 64 128
So for example to set ID number 3, switch 1 & 2 ON, ID number 7, switch 1, 2 & 3 ON.
Soft Address
If you need to change the ID set in the camera it can be done manually as detailed in the
above setting under Hard Address. Alternatively you can set the address using the Soft
Address option.The address range is from 1 ~ 255. In order to supersede the Hard ID address
you will need to switch Soft Addr Enable to ON.
Soft Addr Enable
If you set this from OFF to ON the Hard ID set by the dipswitches in the PTZ camera can be
overwritten.
Camera Type
Camera module installed in PTZ camera.
Internal Temp
Internal temperature of PTZ camera
Software Ver
Software version
Main Menu
System Information
Display Setting
System Setting
IR LED Setting
Restart Camera
Reset
Exit