background image

  www.nitedevil.com 

                                                          XSEE240 

 

NiteDevil Traditional Wide Dynamic HD Cameras  

 

Multi-Format (TVI/AHD/CVI/CVBS) 

 

Email: 

[email protected]

                                                                                                  

Last Revised: 12/04/2018

 

  

 

SYSTEM 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
OUTPUT  
 
 
 
 
 
 
 
 
 
 
 
FRAME RATE 
FREQUENCY 
COM.  
 
 
 
 
 
 
 
IMAGE RANGE  
FULL / COMP / USER 
 
 
COLOR SPACE 
AUDIO MIC 
COLOR BAR 
LANGUAGE 
CAM TITLE 
 
 
RESET ON(Push) 
Return 

 
Main Output Analog  Out  0       /   Out 1 
  Analog Out 0  TVI/AHD/CVI  /   Analog Out1 CVBS 
  Y Gain 0 ~ 32  Def 16              /    Y Gain not used 
  CB Gain 0 ~ 32  Def 119            /     CB Gain not used 
  CR Gain 0 ~ 32  Def 119           /     CR Gain not used 
  Position 0 ~ 256 Def 128          /     Position not used 
  Burst Freq 0 ~ 256 Def 128      /     Burst Freq not used 
  Burst Gain 0 ~ 128 Def  79       /     Burst Gain not used 
  UCC Select0  8  Byte  (

Do not change this

  720 EX  Off/ On 
  UCC Select1 not used 
  Exit 
1080  25P 
50Hz / 60Hz 
COM 
       Cam ID 1 ~ 255  Default 0 
       Baudrate  2400 / 4800 / 9600 / 57600 / 

115200

 

       Set Done On (push) 
       Return       
       FULL / COMP / USER        
                                       Offset 0 ~ 32 (Default 16) 
                                       Return 
 
IMAGE RANGE  
       Offset  0 ~ 32  (Default 16) 
       Return 
HD-CbCr / YUV / SD-CbCr 
(Not Used) 
Off / On 
ENG / CHN / CHN(S) / JPN / KOR 
Off / Right Up          /   Left Down   
        (Use up or down to select character and 
          left or right to select position) 
Hold down Iris+ button for 3 seconds 

 
The SYSTEM menu provides a number of general facilities. These include selecting the correct 
camera format, setting a camera identification number and baud rate for RS485 connection, 
resolution mode, frame rate and colour standard, language, test colour bar, camera title and camera 
reset option. 
 

OUTPUT  

 

 

Main Output Analog  Out 0 /1 

(Out 0 = HD  Out 1 = CVBS) 

        

 

 

 

Analog Out 0  TVI           (Select TVI / AHD / CVI) 

 

 

 

 

Y Gain       0 ~ 32   Default 16        Yellow Gain      

   

 

 

 

CB Gain    0 ~ 32    Default 12        Blue Gain    

   

 

 

 

CR Gain    0 ~ 32    Default 12        Red Gain     

   

 

 

 

Position     0 ~ 256  Default 128      Position     

   

 

 

 

Burst Freq 0 ~ 256  Default 128      Burst Frequency 

   

 

 

 

Burst Gain 0 ~ 128  Default  69       Burst Gain 

   

 

 

 

UCC Select0  8  Byte  (

Do not change this

   

 

 

 

720 EX  Off/ On 

   

 

 

 

UCC Select1 not used 

   

 

 

 

Exit 

 

Содержание SEE240 Series

Страница 1: ...tdoors in housings ensure the housing is large enough to take the traditional camera plus the length of the lens assembly Features 1 28 CMOS sensor Low Light Colour 0 1 Lux B W 0 001 Lux Wide Dynamic Range setting Maximum 1 6 watts power consumption True Day Night SENS UP auto function 2x 32x Built in OSD menu Digital Noise Reduction function Privacy Masking Mirror Flip options Electronic Shutter ...

Страница 2: ...intruder type alarm PSU may give rise to problematic earth loops and poor voltage regulation can give poor noisy image quality The terminal strip will facilitate easier and faster power connection without the hassle of soldering The terminal connection can be seen in the picture on the right The 12V and 0v connections from the power supply must be connected correctly If you have a 2 1mm jack plug ...

Страница 3: ...eed to alter the back focus adjuster which is described previously Setting Up an Auto Iris Direct Drive Lens for different Light Levels The brightness setting in the menu determines when the IRIS of the lens opens and closes It is important to set this correctly as if the brightness level is set too low you may get satisfactory pictures during the day but at night not enough light can enter the ca...

Страница 4: ...ale BNC BNC lead When using a co ax type cable such as RG59 or similar the outer braid of the co ax provides the 0V GROUND connection and the inner core provides the Video connection When you are in correct format press the joystick button in momentarily if you wish to access the menu First power the camera up when it is connected to a monitor or DVR and monitor and see if the required format disp...

Страница 5: ...Z menu in the MEGA TVI or MAX TVI DVRs using the AlienTVI Coaxitron protocol This protocol is generally set in the PTZ Settings menu as default but if not select using the following Enter the DVR Menu click on Video PTZ and select the channel number of the TVI camera connected to the DVR Then click on PTZ Settings and select AlienTVI Coaxitron and click OK Use the directional arrows to move up and...

Страница 6: ...Position Def 2 Disp V_Pos 0 34 Vertical Position Def 12 Disp H_Size 0 60 Horizontal Size Def 12 Disp V_Size 0 34 Vertical Size Def 14 Return EXPOSURE BRIGHTNESS SHUTTER SENS UP AGC RETURN 0 20 Def 10 Auto Manual Flicker Normal Deblur Def Auto Manual 1 25 1 50 1 100 1 200 1 400 1 800 1 1600 1 3200 1 6400 1 12800 1 25600 Def 1 25 Flicker Off x2 x4 x8 x16 x32 Def Off 0 10 Def 10 BACKLIGHT OFF HLC BLC...

Страница 7: ...Level 1 20 Default 7 Delay Low Middle High Return COLOR AWB Auto Autoext Preset Manual Color Gain 1 20 Default 10 Return Preset Push Color Gain 1 20 Default 10 Return MANUAL C Temp 5000K 8000K 3000K Def 5000K R Gain 1 20 Default 10 B Gain 1 20 Default 10 Return DIGITAL NOISE REDUCTION DNR Off Low Middle High Default Middle IMAGE SHARPNESS GAMMA MIRROR FLIP ACE DEFOG PRIVACY RETURN CVBS CVI TVI AHD...

Страница 8: ...AR LANGUAGE CAM TITLE RESET ON Push Return Main Output Analog Out 0 Out 1 Analog Out 0 TVI AHD CVI Analog Out1 CVBS Y Gain 0 32 Def 16 Y Gain not used CB Gain 0 32 Def 119 CB Gain not used CR Gain 0 32 Def 119 CR Gain not used Position 0 256 Def 128 Position not used Burst Freq 0 256 Def 128 Burst Freq not used Burst Gain 0 128 Def 79 Burst Gain not used UCC Select0 8 Byte Do not change this 720 E...

Страница 9: ...0 Horizontal Position Def 2 Disp V_Pos 0 34 Vertical Position Def 12 Disp H_Size 0 60 Horizontal Size Def 12 Disp V_Size 0 34 Vertical Size Def 14 Return This camera has a fixed lens and therefore focus is not adjustable This option is N A Focus Area Middle Wide Narrow Select to create a focus box In the camera menu you can enter the Focus Adjust option and select and area for best focus result by...

Страница 10: ...ghosting but reduce the amount of available light the faster the shutter operates At night the slower the shutter speed the more light is available The Flicker option sets the shutter speed at 1 250 that synchronises with fluorescent tubes so that the pulsing effect is minimised Recommendation is to leave this in Auto SENSUP Off x2 x4 x8 x16 x32 The SensUp option allows the shutter speed to be red...

Страница 11: ...may be best as daytime pictures generally give a more even spread of light apart from sunlight issues Recommend only to use on Night Only if bright lights are causing complete video loss BLC Backlight Compensation H Pos V Pos H Size V Size BLC is the standard setting for low level light differences Select an area where BLC is required Using the H Pos Horizontal Position and V Pos Vertical Position...

Страница 12: ...eir own IR light source this option can give the best results Note that this option has a manual adjustment for setting IR switch on according to lux level from day to night and from night to day plus an option for applying a delay factor This stops switching until a pre determined lux level remains constant There is also the option to switch off the IRs Recommend to try this option as camera has ...

Страница 13: ...k centre button down MANUAL Use this option to manually balance light levels Note that the manual option is used for a static light environment and generally suitable for cameras installed indoors using constant artificial light C Temp 5000K 8000K 3000K R Gain 1 20 Default 10 Sets Red Gain B Gain 1 20 Default 10 Sets Blue Gain Return RETURN Return to main menu DIGITAL NOISE REDUCTION DNR Off Low M...

Страница 14: ...epending on the camera format selected the format s will be in dark type for adjustment The sharpness control is done by digital correction and the best way to set this option is to set level to maximum of 10 then flick back to 1 to see the difference Then adjust to display sharpest picture without displaying heavy black lines around subjects Gamma 0 55 0 65 0 75 0 45 Default 0 55 Gamma correction...

Страница 15: ... creation of up to 16 coloured areas to be created to provide privacy masking Zone Disp Off On The Zone Display allows you to switch on and off the zone number H Pos V Pos H Size V Size Each area can be positioned using the H Pos horizontal position VPos vertical position and sized using the H Size horizontal size and V Size vertical size options The Zone Display allows you to switch on and off th...

Страница 16: ...he picture and as motion is detected in these areas the areas will be displayed with red moving boxes DET WINDOW Enter to select window number Window Zone 0 3 Window Use On Off Det H Pos nn Set horizontal position Det V Pos nn Set vertical position Det H Size nn Set horizontal size Det V Size nn Set vertical size Each area can be positioned using the H Pos horizontal position VPos vertical positio...

Страница 17: ...one On push Return FULL COMP USER Offset 0 32 Default 16 Return IMAGE RANGE Offset 0 32 Default 16 Return HD CbCr YUV SD CbCr Not Used Off On ENG CHN CHN S JPN KOR Off Right Up Left Down Use up or down to select character and left or right to select position Hold down Iris button for 3 seconds The SYSTEM menu provides a number of general facilities These include selecting the correct camera format...

Страница 18: ...Return IMAGE RANGE Full Comp User Offset 1 32 Default 16 Return COLOR SPACE HD CbCr High Definition Chrominance Blue and Red YUV Allows grayscale adjustment Y luminance UV colour SD CbCr Standard Definition Chrominance Blue and Red AUDIO MIC Not used COLOR BAR Off On Useful for testing camera colour quality LANGUAGE ENG CHN CHN S JPN KOR Select language required CAM TITLE Off Right Up Left Down En...

Страница 19: ...nal Motion Detection On Off 4 zone selectable Privacy Masking On Off 16 zone selectable Digital Noise Reduction 2D 3D DNR On Off Selectable Sens up NiteDevil function Off 2x 4x 6x 8x 16x 32x Working Temperature 10 C 50 C Humidity 90 Storage Temperature 10 C 60 C Menu Control Menu Control via joystick or using Coaxitron Supplied Voltage 12vDC 12vDC 24vAC Power Consumption 130mA 12V DC 177mA 24vAC 1...

Отзывы: