Construction and function
Variable Message Sign
32
3.5.11 Maintenance
The battery of the remote control must be charged at regular intervals (see the battery symbol on the
display). The operating time during radio operation with the integrated battery is 12 hours. As soon as
the remote control is placed on the charging station, it is charged by an automatic battery charger. If
there is a cable connection, the remote control is charged via the cable connection. The charge status
is indicated by an incremental battery symbol on the display. If the symbol is static at 100%, the
battery is fully charged.
3.5.12 Declaration of conformity
The remote control Pro-Remote II fulfills all essential requirements of the European Guidelines
1999/5/EG, 2004/108/EG and 2006/95/EG provided that it is used for the intended purpose and in
accordance with the operating instructions of the manufacturer.
A declaration of conformity according to directive 1995/5/EG is available and can be requested at:
Adolf Nissen Elektrobau GmbH + Co.KG
Friedrichstädter Chaussee 4
25832 Tönning
Tel: +49 (0)4861 612-0
4
Mounting and installation
4.1
Mounting
The rear side of the variable message sign is equipped with 2 C-
profile rails (HM 38/17) where it can be mounted with the enclosed
HALFEN™ screws (see chapter "construction and function").
NOTE!
Variable message signs must be mounted as flat as possible on the frame without distortion! All bolted
connections must be secured against loosening!
4.2
Installation
The installation and mounting of the variable message sign VarioSign has to be carried out by the
customer (qualified personnel) according to locally applicable regulations and in compliance with
statutory requirements. The mounting must only be done on sustainable and approved fastening
systems.