Nippon DLCAP Скачать руководство пользователя страница 11

DLCAP

TM

MODULE

 

Data sheet

     

                                                       

MDXE7R5S461PB3111B

 

Nippon Chemi-Con Corporation 

                 

                           

         

11 

(1)

過電圧検知回路電気的仕様

Electric specification of the over voltage detection circuit

 

 

(2)

過電圧検知回路用ユーザーシステム要求仕様

 

Required specification of the user system for over voltage detection circuit 

 

※ユーザーシステムでの動作検証を実施し、確実な動作の検証をお願いします。

 

*Please do operational test in your system and verification of certain performance.

 

項  目

    Item 

仕様

Specification 

備考

    Note 

過電圧検知回路設定電圧

(

単セル電圧

Over  voltage  detection  circuit  setup 

voltage(Single cell voltage) 

2.94 [V]±2.0%   

2.88

3.00 [V] 

フォトモスリレー耐圧   

Withstand  voltage  of  the  photo  MOS 

relay

 

AC2.5[kV] 

セル端子

/

故障検出信号端子間

 

Between  cell  terminal  and  over  voltage 

detection signal terminal 

フォトモスリレー品番 

Photo MOS relay No.

 

AQY412EHA 

(Panasonic) 

素子単品最大絶対定格

 

Absolute maximum value of the single device 

出力側負荷電圧

(

ピーク

AC)    Output side load 

voltage (peak AC)

60[V] 

出力側最大出力損失

  Output  side  maximum 

output loss

500[mW] 

出力側最大オン抵抗

  Output  side  maximum 

on resistance

2.5[

Ω

ON 抵抗 

On resistance

 

MAX 3[

Ω

モジュール

1

(

セル

3

直列

)

毎の抵抗

 

フォトモスリレー

ON

抵抗と配線抵抗合計

 

One module(per 3 cells series connected) 

resistance 

Photo  MOS  relay  ON  resistance  and  wiring 

resistance 

項  目

    Item 

仕様

Specification 

備考

      Note 

2

次側絶対最大定格電流

 

Secondary 

side 

absolute 

maximum current value 

0.55[A] 

ピ ー ク 負 荷 電 流

Peak  load  current 

1.5[A]100ms(1shot) 

推奨電流 

250[mA]

以下

 

Recommended current 250[mA]or less 

2 次側最小電流 

Secondary side minimum current

 

1[mA] 

フォトモスリレー開路時漏れ電流

 

最大

10[

μ

A] 

Photo MOS relay open leak current   

Max 10[

μ

A] 

2 次側絶対最大定格入力電圧 

Secondary 

side 

absolute 

maximum input voltage value

 

30[V](

ピーク

AC) 

30[V](Peak AC) 

推奨電圧 

DC24[V]

以下

 

Recommended voltage DC24[V] or less 

Table 3-3.

 Specifications list of the over voltage detection circuit & I/F 

Table 3-4.

 Specification list of the user system for over voltage detection circuit 

 

Содержание DLCAP

Страница 1: ...2 Reference Specification Model Name DLCAPTM MODULE Product Number MDXE7R5S461PB3111B Nippon Chemi Con Corporation Japanese notation has priority over English notation if any doubt arises between Japa...

Страница 2: ...mounted inside user system and not supposed to be exposed directly to rain wind sunlight dust etc Charge discharge causes the self heat generation inside the cells in the module Please consider coolin...

Страница 3: ...re sensor 14 4 Mechanical specification 16 4 1 Mechanical specification of the module 16 4 2 Appearance 17 4 3 Label figure 18 4 4 Fixing and connection of the module 19 4 5 Packing specification of t...

Страница 4: ...equipment is 3pcs connection of electric double layer capacitor DLCAPTM hereafter it is called cell in series hereafter this configuration is called module 2 Voltage balance circuit is mounted to prev...

Страница 5: ...le 1 1 Please disconnect the short cable when the module is used The short cable has a short cable attention tag 2 I F RETURN Figure 3 4 2 Please remove I F connector RETURN when modules are connected...

Страница 6: ...ist of the module accessories No part name No of pcs Parts appearance Connecting bus bar 1 Fixation screw for connecting plate 3 8 PT 8 Connecting plate 2 3 The above three points are accessories that...

Страница 7: ...shown in Figure 2 3 DLCAPTM cell Figure 2 2 Block diagram Power terminal Balance Failure detection circuit substrate C3 C2 C1 Thermistor Power terminal I F Connector IN I F Connector OUT Thermistor H...

Страница 8: ...at max charge Nominal capacitance 466 F 10 15 396 to 512 F initial measurement condition 20 10 A DCIR 4 2 m or less initial measurement condition 20 charge open 10 A 1 Sec Dielectric voltage AC 2 5 kV...

Страница 9: ...ET turns on and current flows on balance resistance to control cell voltage increase Item Specification Note Balance circuit setup voltage 2 4 V 2 5 2 34 to 2 46 V Balance circuit current 104 7 mA 5 c...

Страница 10: ...ormal state is short Abnormal state is open If over voltage 2 94V or higher is detected from either of 3 cells it transmits the anomalous occurrence to outside system by changing the state of photo MO...

Страница 11: ...e of the single device AC Output side load voltage peak AC 60 V Output side maximum output loss 500 mW Output side maximum on resistance 2 5 ON On resistance MAX 3 1 3 ON One module per 3 cells series...

Страница 12: ...of I F connector IN shows SHORT state through photo MOS relay when I F Connector RETURN is connected to I F Connector OUT at normal operating condition It shows OPEN state at abnormal operating condit...

Страница 13: ...er module as Figure 3 4 when you connect 2 modules Overvoltage detection circuit works in the same way when 3 or more modules are connected 2 1 3 I F Connector OUT I F Connector RETURN 3 3 2 2 1 1 I F...

Страница 14: ...tics of the thermistor Item Specification Note Sensor model No 103AT SEMITEC SEMITEC Corporation Connector model No PALR 02VF J S T MFG CO LTD PAP 02V S JST Correspondence connector specification PAP...

Страница 15: ...esistance 40 188 5 k 30 111 3 k 20 67 77 k 10 42 47 k 0 27 28 k 10 17 96 k 20 12 09 k 25 10 00 k 30 8 313 k 40 5 827 k 50 4 160 k 60 3 020 k 70 2 228 k Table 3 6 Resistance Temperature Table 3 5 Resis...

Страница 16: ...cover material PC PBT GF30 Holder Pillar material PBT GF30 UL94V 0 Flame retardant grade UL94V 0 Cell connection method Connect cell terminals with bus bars then fix with screw JIS A5052 H34 Bus bar...

Страница 17: ...DLCAPTM MODULE Data sheet MDXE7R5S461PB3111B Nippon Chemi Con Corporation 17 4 2 Appearance Figure 4 1 Outline of the module Rating label Short cable 6 Module fixing holes total 6 spots...

Страница 18: ...E Data sheet MDXE7R5S461PB3111B Nippon Chemi Con Corporation 18 4 3 Label figure 1 Rating label figure Figure 4 2 Outline of the rating label Model code Rated voltage and nominal capacitance initial S...

Страница 19: ...is module to user system Refer to Figure 4 1 recommended screw size M5 4 8 3 Nm 10 Please select appropriate type and length of the fixation screws to fit user system and fix with appropriate torque T...

Страница 20: ...connect plural modules with attached parts as shown Figure 4 3 No Part name No of pcs Note Connecting bus bar 1 3 8 PT Fixation screw for connecting plate 8 0 6Nm 10 Recommended tightening torque 0 6N...

Страница 21: ...orporation 21 4 5 Packing specification of the module 1 Packing specification of the module 2 Packing specification of the accessories Figure 4 4 Outline of the packing specification of the module Fig...

Страница 22: ...Resistance Change Table 3 1 1200 1200 of the value given in Table 3 1 Load Life Test 70 2 000 20 After the modules are subjected to the rated DC voltage at 70 for 2 000 hours the following specificati...

Страница 23: ...ata sheet MDXE7R5S461PB3111B Nippon Chemi Con Corporation 23 7 Environmental protection EU RoHS This product corresponds to RoHS of EU 2013 12 6 Corresponds to exclusion of 6 regulated materials Confi...

Страница 24: ...ion should be all right after the test 2 Heat shock 40 6 r 70 6hr 1 20 Following test is done 20 cycles 40 deg C 6hours and 70 deg C 6hours is determined as 1 cycle here Appearance module specificatio...

Страница 25: ...eleration rate 1G frequency range 5 200Hz log sweep 10min vibration period each 1 5hour x 3axis XYZ total 4 5hour Appearance module specifications screw torque and circuit operation should be all righ...

Страница 26: ...rrow on the top cover points upward See figure below Please contact us for installation at an angle exceeding horizontal 2 Temperature characteristics heat generation Electric double layer capacitor c...

Страница 27: ...degradation or failure No protection circuit against over or reverse voltage is installed in this module Please consider to add protection circuit at user system if necessary in case abnormal voltage...

Страница 28: ...fore please take care especially when a number of capacitors are connected in series and stored It is recommended to short circuit between terminals and store for safety 4 Environment to avoid Please...

Страница 29: ...firm polarity to avoid reverse connection 3 Caution for drop Please do not drop the module Please do not use the module once it has been dropped on the floor 4 Prohibition of deformation Please do not...

Страница 30: ...pection 9 5 Please carry out periodic inspections for the module that has been for industrial application Please refer to 9 5 Maintenance inspection for inspection contents 3 Abnormal state a If the m...

Страница 31: ...elmet for inspection b Before inspection turn off the power of the equipment and discharge the module voltage to safe level c 0V Voltage of electric double layer capacitor increases by restriking volt...

Страница 32: ...MDG Code Regarding the exportation of electric double layer capacitor a minimum of requirements and evaluation criteria for the shippers to perform are issued based on recommendation regarding hazardo...

Страница 33: ...2370C Safety Application Guide for fixed electric double layer capacitors 2 Guidelines of the transport of fixed electric double layer capacitors for use in electric and electronic equipment Contact...

Отзывы: