32
Table 8
Number
Error code
Error
1
E1
Compressor high pressure protection
2
E2
Indoor anti-freeze protection
3
E3
Compressor low pressure protection, refrigerant lack
protection and refrigerant colleting mode
4
E4 Compressor high discharge temperature protection
6
E6
Communication error
9
E9
Full water protection
10
F1
Indoor ambient temperature sensor is open/short circuited
11
F2
Indoor evaporator temperature sensor is open/short circuited
12
F3
Outdoor ambient temperature sensor is open/short circuited
13
F4
Outdoor condenser temperature sensor is open/short circuited
Outdoor discharge temperature sensor is open/short circuited
14
F5
15
C5
16
EE
Note:
If there're other error codes, please contact qualified professionals for service.
When the unit is connected with the wired controller, the error code will be simultaneously
shown on it.
5
E5
8
E8
7
E7
Loading EEPROM malfunction
Anti-high temperature protection
Jumper cap malfunction protection
AC over-current protection
Mode conflict
Cassete - Multi-Split
Содержание MB12 GA