Nipon Coolair MB12 GA Скачать руководство пользователя страница 1

Installation and User Manual

Air conditioning

Cassette - Multi-Split 

Thank you for choosing our product. For proper operation, please read this manual carefully and keep this 

manual. If you lose the user manual, contact the installer, or visit www.nipon-coolair.com, or send an e-mail 

to [email protected] to obtain the digital version.

Содержание MB12 GA

Страница 1: ...Thank you for choosing our product For proper operation please read this manual carefully and keep this manual If you lose the user manual contact the installer or visit www nipon coolair com or send...

Страница 2: ...the environment or human health from un controlled waste disposal recycle it responsibly to promote the sustainable reuse of mate rial resources To return your used device please use the return and co...

Страница 3: ...uction for icons on display screen 4 3 3 Introduction for buttons on remote controller 5 3 4 Function introduction for combination buttons 9 5 Installation of the Unit 14 5 1 Installation of the Indoo...

Страница 4: ...ied personnel may be dangerous The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heate...

Страница 5: ...an extension cord Do not put other loads on the power supply use a dedicated power circuit 8 Firmly clamp the interconnecting wires so their terminals receive no external stresses Incomplete 9 After c...

Страница 6: ...ge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety 18 Children should be supervised to ensure that they do not play with...

Страница 7: ...inage device 2 Drainage pipe 4 Connection pipe 5 Wired Controller 6 Wireless Controller 7 Big handle 8 Liquid Pipe 9 Gas pipe 10 Drainage pipe 11 Front Board Indoor Outdoor 2 3 4 7 5 6 1 8 9 10 11 Air...

Страница 8: ...d signal Turbo mode X fan mode Set temperature Set time TIMER ON TIMER OFF Child lock Up down swing Set fan speed AIR function I feel Light Temp display type Set temp Outdoor ambient temp Indoor ambie...

Страница 9: ...F F F Note Note 1 2 T F RY T Cassete Multi Split...

Страница 10: ...set Do not put the remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature Press this button to set HEALTH function ON or O...

Страница 11: ...r timer on After pressing this button icon disappears and the word ON on remote controller blinks Press or button to adjust TIMER ON setting After each pressing or button TIMER ON setting will increas...

Страница 12: ...he constant circulating valid After that air conditioner will be turned on or turned off according to setting time ON OFF button has no effect on setting If you don t need this function please use rem...

Страница 13: ...off display light on indoor unit icon on remote controller disappears Press this button again to turn on display light icon is displayed SLEEP button LIGHT button 14 15 r temperature indicator on ind...

Страница 14: ...of battery box along the arrow direction 2 Replace two 7 AAA 1 5V dry batteries and make sure the position of polar and polar are correct 3 Reinstall the cover of battery box signal sender battery Co...

Страница 15: ...sket from falling off 6 Wireless Controller Battery 1 2 To control the indoor unit 7 sealing plaster 1 8 Fastener 4 To fasten the sponge 9 Insulation 1 To insulate the gas pipe 10 Insulation 1 To insu...

Страница 16: ...ake sure that there are enough space for care and maintenance and the height fall between the indoor unit and ground is above 1800mm 7 When installing the suspension bolt check if the installation pla...

Страница 17: ...cooling and heating effect performs 4 4 Electrical Requirement Electric Wire Size and Fuse Capacity Table 4 Indoor Units Power Supply Fuse Capacity Min Power Supply Cord V Ph Hz A mm2 12 24k 220 240V...

Страница 18: ...stallation of the Indoor Unit 1 1 Indoor unit dimension For the units 12 18k For the units 24k Fig Table Item Model A B C D E F G MB 12 GA 670 666 600 496 145 240 596 MB 18 GA MB 24 GA 950 840 780 680...

Страница 19: ...he water pump and the 5 Remove the gasket anchor board and tighten the nut remained 6 Remove the paper template 1 3 Installing the Suspension Bolts 1 Using the installation template drill holes for bo...

Страница 20: ...t is horizontal as shown below Horizontal tester Fig 8 Fig 9 2 Installation of the Connection Pipe 2 1 Flare Processing 1 Cut the connection pipe with the pipe cutter and remove the burrs 2 Hold the p...

Страница 21: ...and secure it with tape Fig 11 Pipe Cutter Cutt line Heat insulating pipe CAUTION To prevent breaking of the pipe avoid sharp bends Bend the pipe with a radius of curvature of 150 mm or over If the p...

Страница 22: ...pe to see if it leaks then take the treatment of heat insulation as shown in the Fig 12 Use the medium sized sponge to insulate the coupler of the gas pipe Fig 12 Table Flare nut tightening torque Pip...

Страница 23: ...ulation on the Pipe Joints Indoor Side Only Stick coupler heat insulation large and small to the place where connecting pipes Fig 14 2 7 Liquid Pipe and Drain Pipe If the outdoor unit is installed low...

Страница 24: ...in case of refrigerant leak 3 Connect the hose used for evacuation to the vacuum pump 4 Open the switch at the lower pressure side of the manifold valve assembly and start the vacuum pump Meanwhile th...

Страница 25: ...the manifold valve assembly to two service ports to quicken the evacuating speed 7 Slightly open the liquid valve and let some refrigerant go to the connection pipe to balance the pressure inside and...

Страница 26: ...ain hose Insulating tape accessory Fig 19 5 4 2 Installing the Drain Pipes 1 Insert the drain pipe to the drain outlet of the unit and then tighten the clamp securely with tape 2 Connect the extension...

Страница 27: ...inage side of each indoor unit Fig 21 6 Install one water trap for each unit 7 Installation of water trap shall consider easy cleaning in the future Fig 21 Fig 22 Fig 23 8 Connection of drainage branc...

Страница 28: ...he drain hose to the drain lift pipe and insulate them 2 Connect the drain hose to the drain outlet on the indoor unit and tighten it with the clamp Drain lift pipe Fig 27 4 Secure a downward gradient...

Страница 29: ...ter pot The length of the pipe should be about 100mm Above 100mm Drain vent for repair use plastic stopper is included drain the water in waterspoit by this outlet vent Fig 5 The Panel Installation 5...

Страница 30: ...3 4 Fig 3 5 2 Installing the Panel 1 2 Latch other two hooks 3 Tighten four hexagonal screws under the latches about 15mm 4 Adjust the panel along the direction indicated by the arrow as shown in Fig...

Страница 31: ...rcuit and install a special receptacle to supply power to the air conditioner The special branch circuit breaker is installed in the permanent wiring Always use a circuit that can trip all the poles o...

Страница 32: ...bend the solid wire to form a loop suitable for the terminal screw 4 Shape the loop wire properly place it on the terminal board and tighten securely with the terminal screw using a screwdriver 2 For...

Страница 33: ...d colors with those of the indoor unit side Erroneous wiring may cause burning of the electric parts Always fasten the outside covering of the connection cord with cord clamps If the insulator is not...

Страница 34: ...Electric wiring of indoor unit side Remove the electric box cover from the electric box sub assy and then connect the wire Power supply terminal board Seal here to avoid leakage Fig 3 Cassete Multi S...

Страница 35: ...d on the corresponding marks as shown in Fig 3 Ground both the indoor and outdoor units by attaching a ground wire Unit shall be grounded in compliance with the applicable local and national codes 6 I...

Страница 36: ...erature sensor is open short circuited 12 F3 Outdoor ambient temperature sensor is open short circuited 13 F4 Outdoor condenser temperature sensor is open short circuited Outdoor discharge temperature...

Страница 37: ...e controller the dual 8 nixie tube set under on status displays indoor temperature for 3s and then resume to display the set temperature If there is error error code will be displayed If there s multi...

Страница 38: ...ource or too many people inside the room The door or window is open There is obstacle at the air intake or outlet The set temperature is too high There is refrigerant leakage The performance of room t...

Страница 39: ...s installed in a room where the air is extremely 1 Open the air inlet grille 1 How to open the panel grille of the 24k cassette type unit Push the buckle as shown in the Release the screws under buckl...

Страница 40: ...t and remove the grille Filter screen Filtering element Support Bolt up wash it by warm water meld with the Note Never use hot water over 45 C in case of color fading or turning yellow The same as ste...

Страница 41: ...is well ventilated The continuous ventilation status should be kept during the operation process Check whether there is fire source or potential fire source in the maintenance area The naked flame is...

Страница 42: ...ling appliances specialized for R32 Make sure that different kinds of refrigerant won t contaminate with each other After filling is finished please do the leakage detection before test running anothe...