Special or critical User Instructions 

1.  The mask should be used with the valve cap, unless it is used with the Micro 

Ventilator device (available separately). Do not remove the mask or change 
its accessory unless you are in an uncontaminated area. 
 

2.  If this respirator is intended to be used with the micro ventilator, OSHA fit 

testing should be performed with the ventilator turned on. 

 
3.  Model AP522VL filtering facepiece has been manufactured by Champak 

Enterprise Co., Ltd. for Innosparks Pte Ltd under TC-84A-7842. 

Safety and Precaution 

1.  The  Micro  Ventilator  contains  lithium  polymer  battery.  Improper  use  or 

storage may result in battery leak or expansion, and may cause conflagration, 
property loss or health harm. 

2.  Operating temperature range of the Micro Ventilator is from -5°C to 35°C. Do 

not  expose  Micro  Ventilator  to  fire  or  high  temperature.  When  not  in  use 
please store the Micro Ventilator in a clean, cool and dry atmosphere. 

3.  Micro  Ventilator  is  rated  IP53.  However,  it  should  not  be  washed  or 

submerged into water. 

4.  The  Micro  Ventilator  should  only  be  charged  using  proper  certified 

micro-USB cable (supplied) and socket. 

5.  Please  disconnect  any  cable  from  Micro  Ventilator  before  using  it  on  the 

respirator.  Do  not  short-circuit  battery.  Do  not  reverse-charge  or 
reverse-connect. 

6.  Do  not  drop,  shake,  puncture  or  disassemble  the  Micro  Ventilator  or  its 

components. Once the Micro Ventilator or its components are damaged, do 
not continue to use it. 

7.  Please  dispose  all  parts  in  accordance  to  local  regulation.  The  lithium 

polymer battery should be recycled and should not be disposed as general 
litter. 

8.  The “Lot” code represents the production date in yyyy/mm/dd format. 
 

Содержание AP522VL

Страница 1: ...fication is allowed to the respirator The respirator should not be worn when it is contaminated eg dusty wet etc or damaged eg Broken part hole etc The contaminated or damaged respirator must not be u...

Страница 2: ...signated waste receptacle 8 The Lot code represents the production date in yyyy mm dd format The Exp represents the expiry date in yyyy mm dd format Storage The respirator must be stored in its origin...

Страница 3: ...micro ventilator before wearing the respirator 2 The operating time of the Micro Ventilator is estimated at 2 5 hours The respirator can still be used independently even when the micro ventilator sto...

Страница 4: ...isinfect please wipe its surface with a damp and soft cloth or wet tissue or alcohol wipe Do not use strong chemical or abrasive solvent to clean the Micro Ventilator Please ensure that the Micro Vent...

Страница 5: ...5 User Instructions for Respirator...

Страница 6: ...nose clip into a shape for a proper fit 4 The respirator strap can be adjusted for proper fit Pull the strap outwards at either side of the buckle for tighter fit push the strap inwards at either sid...

Страница 7: ...e range of the Micro Ventilator is from 5 C to 35 C Do not expose Micro Ventilator to fire or high temperature When not in use please store the Micro Ventilator in a clean cool and dry atmosphere 3 Mi...

Страница 8: ...ny liability for any damages including but limited to direct indirect special or consequential damages arising out of resulting from or in any way connected to the use of the product whether or not ba...

Страница 9: ...or health C Do not exceed maximum use concentrations established by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators...

Страница 10: ...ness or any other sign of distress occurs 5 Ensure proper fit on your face before using the respirator 6 The respirator should not be worn under condition preventing a proper fit on your face Such con...

Страница 11: ...11 Innosparks Pte Ltd 75 Ayer Rajah Crescent 02 13 Singapore 139953 Model number AP522VL Made in Taiwan...

Отзывы: