background image

                                                                  

25 

Integral Installation

 

[ Space and location ]

 The total height of wind sensor is 838mm. It should 

be horizontally installed on the ventilated place of ship and the action radius 

of wind indicator and wind cup is over 550mm.   

Please note, big Radar antenna rotation can disturb 

the wind measurement. Find a location away from 

Radar.

 

[ Integral fixation ]

   Use U-bolt in the accessory to fix wind sensor and the 

best option of supporting tube diameter is 60mm. 

[ Wiring ] 

4-core  screened  cable  with  external  diameter  4mm~6mm  is 

connected  with  4  terminals  +

-

B

A  through  glands  of  junction  box. 

Please  pay  attention  on  wire  colors  and  sequence  in  order  to  correctly 

connect the wiring terminals of back cover, 1+ 2- 3B 4A.   

[ Calibration ]

 After the installation of main unit of wind sensor, do the 

calibration of wind direction based on Calibration. 

 

 

 

 

 

 

 

 

 

 

 

AM706D back cover terminals

后盖端子

 

DC 

NMEA 

AM706S junction box terminals 

Содержание AM706D

Страница 1: ...Model AM706D Weather Station Operation Manual Document NLT AM706D SSEN Edition V140827...

Страница 2: ...ess any button to mute Selectable Relative True speed direction Selectable day and night modes Direction calibration After power on move wind vane toward the ship bow direction then press the reset bu...

Страница 3: ...r or rain into unit Operation Warn Do not refit unit privately Installation Warn Do not operate with water Be sure the main unit location is IP23 If water leakage Power down immediately Be sure the wi...

Страница 4: ...r NMEA0183 7 GPS data input RMC 7 GPS data input GGA data input 8 GPS data input VTG 8 Speedlog data input VBW 9 Gyro data input HDT 9 Main unit output MWV 9 Main unit output MDA 10 Main unit output M...

Страница 5: ...Mounting 22 Power Adapter Installation 23 Installation of Wind sensor AM706S 24 Wind Vane and Wind Cup Installation 24 Integral Installation 25 Temperature and Humidity Sensor Installation 26 Tempera...

Страница 6: ...larly print these parameters and time longitude and latitude ship speed and navigational signal It is important and necessary for observation and safe navigation AM706D is approved by China Classifica...

Страница 7: ...S485 to main unit through junction box Barometric pressure signal is received from internal IC sensor of main unit Main unit uses these signals to calculate display and export True speed and direction...

Страница 8: ...3 System Introduction General View...

Страница 9: ...Constitution Wind direction and speed sensor holder and junction box Wind direction sensor Wind indicator with empennage and weight and absolute value angle sensor near axis Wind speed sensor Three wi...

Страница 10: ...power input 2 channels Temperature humidity input 1 channel NMEA0183 input 3 channels NMEA0183output 2 channels Printer output 1 channel Sound light alarm output 1 channel Power supply DC24V 20 32V O...

Страница 11: ...ccuracy 1 Wind speed range 1 2 25m s Wind speed accuracy 5 min 0 1m s Min start speed 1 2m s Temperature range 20 80 C Temperature accuracy 0 5 C Humidity range 0 100 RH Humidity accuracy 4 5 RH Barom...

Страница 12: ...l ll a yyyyy yy a x x x x xxxxxx x x a h h CR LF 1 UTC of position fix 2 Status A data valid V navigation receiver warning 3 Latitude 4 Latitude N S 5 Longitude 6 Longitude E W 7 Speed over ground kno...

Страница 13: ...f precision 9 Antenna altitude above below mean sea level geoid 10 Units of antenna altitude m 11 Geoidal separation 12 Units of geoidal separation m 13 Age of differential GPS data 14 Differential re...

Страница 14: ...alid 7 Stern transverse water speed Knots 8 Status stern water speed A data valid V data invalid 9 Stern transverse ground speed Knots 10 Status stern ground speed A data valid V data invalid 11 Check...

Страница 15: ...ction 14 Wind direction unit degree T true 15 Relative direction 16 Relative direction degree M Relative 17 Wind speed 18 Wind speed unit N knots 19 Wind speed 20 Wind speed unit M m s 21 Checksum val...

Страница 16: ...and ship bow 7 H HUM alarm Set Value Press H HUM to set alarm value or turn off 8 Current relative HUM Display current relative humidity No Display Explanation 1 Current relative tr ue wind speed Pres...

Страница 17: ...dow and observe input signal Key Introduction Switch on off 0 OFF 1 ON Gust Alarm OFF 1 25m s High Temperature Alarm 20 80 OFF Low Temperature Alarm OFF 20 80 High Humidity Alarm OFF 1 99 RH Print Set...

Страница 18: ...m When power failure alarm is triggered the main unit buzzer provides long tone alarm external alarm will not be on when power failure and red words Power Failure are flashing Alarm Mute When alarm is...

Страница 19: ...ned on wind value color turns yellow to red and continuously flashing H TMP High Temperature Alarm Press left right arrows of H TMP to set the high temperature alarm and factory setting is OFF Set Val...

Страница 20: ...continuously flashing H HUM High Humidity Alarm Press left right arrows of H HUM to set the high humidity alarm and factory setting is OFF Settings OFF 1 99 RH When current relative humidity is less...

Страница 21: ...0 seconds DPU 414 Printer Setup Dip SW 1 1 OFF Input Serial 2 ON Printing Speed High 3 ON Auto Loading ON 4 OFF Auto LF OFF 5 ON Setting Command Enable 6 OFF Printing 7 ON Density 8 ON 100 Dip SW 2 1...

Страница 22: ...nd 321 3 2m s 2 Temperature 16 2 Humidity 64 0 RH Barometer 1008hPa 3 03 08 32 01 2524N 118 42 0208E Heading 190 4 Speed 0 0Knots Note Do not print the messages on the third line when no GPS or course...

Страница 23: ...nal window observe gyro speedlog GPS signal input situation Speed Unit m s km h kn Gust alarm and current measured values automatically convert with speed unit conversion Temperature Unit C F H L TEMP...

Страница 24: ...Sensor Part When there is ice or dirt on sensor to disturb the normal work please clear in time Regularly check external mounting bolts to avoid looseness and the abrasion and ageing of cables When t...

Страница 25: ...de Then open the junction box Press the calibration button in the waterproof junction box and display relative wind direction zero on main unit Close the waterproof junction box The groove on box body...

Страница 26: ...n unit Installation AM706D The Main unit has three mounting methods table hanging and flush mounting Table and Hanging Mounting The holder supplied by original factory setting is used in table and hun...

Страница 27: ...The holder supplied by original factory setting should be used in flushing mounting Embed the main unit into the bridge control panel the dimension is shown below and tighten the rotary knob to fix t...

Страница 28: ...23 Power Adapter Installation Power adapter GA 240150 AC220 110V to DC24V adapter holder and screws Unit mm...

Страница 29: ...o black seal ring plane washer spring washer and 2 screw nuts The two screw nuts should be tightened and then insert the cotter Wind Cup Wind cup is installed on the bottom of sensor holder successive...

Страница 30: ...n Use U bolt in the accessory to fix wind sensor and the best option of supporting tube diameter is 60mm Wiring 4 core screened cable with external diameter 4mm 6mm is connected with 4 terminals B A t...

Страница 31: ...rature and Humidity Sensor AM706TH Temperature and humidity sensor AM706THcan be installed in hung and fixed link mounting methods AM706TH with M10 bolt is installed on the vertical wall or with U blo...

Страница 32: ...27 Wiring explanation Wiring diagram of AM706D back cover...

Страница 33: ...28 System internal connection System internal wiring diagram...

Страница 34: ...t AM706D 4 core screened cable with external diameter 3mm 6mm is connected with 4 terminals B A through glands of junction box Please pay attention to wire colors and sequence in order to correctly co...

Страница 35: ...30 Main unit AM706D Power in Connect DC cable and ac power adapter GA 240150 with ship power...

Страница 36: ...31 System external connection System external wiring diagram...

Отзывы: