background image

3

/

15

These merchandisers are designed for indoor operation with a recommended operating room
ambient temperature of 75° F (24° C)/55% rh. Their performance is affected by store air currents
when the doors are open. Do NOT allow air conditioning, electric fans, or open doors and
windows to create air currents around these merchandisers nor should they be exposed to direct
sunlight or other heat sources.

NOTE: The condensing unit draws ambient air through the front of the unit and discharges hot air
out the rear of the unit. In order to maintain proper refrigerator performance and compressor life,
a minimum

space of 4” (10 cm) must be maintained between the refrigerator and

surrounding surfaces.
2. PREPARATION OF CABINET FOR OPERATION

Removing Cabinet From the wooden Pallet
Move the merchandiser as close as possible to its permanent location. Check refrigeration
lines to see that they are “free” and no damage has occurred during shipping. Check fan
blades for free operation.

2.1 Leveling Cabinet

These merchandisers must be installed level

(front to back and end to end) to permit maximum draining of the condensate water as well as

proper door alignment and operation.

The merchandiser has been shipped with 6 adjustable foot bolts installed. Level the unit by

placing a level on the merchandiser and make it to level by adjusting the foot bolts.
2.2 Shelf Installation
After the cabinet has been leveled and is in its final position, the shelves may be installed.
Shelf spacing is adjustable by positioning the shelf supports according to your loading
requirements.

WARNING

(Freezer. Models) Do NOT place product directly on floor of merchandiser. Locate

bottom shelf in the lowest position to the floor of the merchandiser (approximately 3” [7.5
cm] off bottom) before loading. Failure to comply may result in product loss.

Содержание F2DH2080-01

Страница 1: ...PRODUCT AND KEEP IT FOR FUTURE REFERENCE Ningbo Wanquan Electrical appliance Company 195 Beixing road Mazhu town Yuyao county Ningbo city Zhejiang province China Table of Contents SHIPPING DAMAGE Gen...

Страница 2: ...e and during unloading This equipment has been carefully inspected at factory and the carrier has assumed responsibility for safe arrival If damaged either apparent or concealed claim must be made to...

Страница 3: ...possible to its permanent location Check refrigeration lines to see that they are free and no damage has occurred during shipping Check fan blades for free operation 2 1 Leveling Cabinet These merchan...

Страница 4: ...t the door should close and seal 2 4 Fan Cycle Switch Hinged doors freezer only The evaporator fan is cycled off upon a door opening by a switch located above each door This reduces the amount of warm...

Страница 5: ...809 52 8 1340 Specification Model R2DH2080 01 F2DH2080 01 Classification Refrigerator Freezer Overall size W x D x H inch 52 8 64 x 31 9 64 x 84 7 64 1340 x 809 x 2151 mm 52 8 64 x 31 9 64 x 84 7 64 1...

Страница 6: ...z R290 4 94oz Compressor hp 1 4 hp 3 4 hp Cooling Type Forced air Defrost Off cycle Electric heater Insulation Polyurethane Cyclopentane CFC Free Temperature control type Auto Power supply 115V 60Hz 1...

Страница 7: ...ON 5 1 Electrical Supply WARNING Equipment MUST be GROUNDED Wiring of the unit is complete when it is shipped from the factory The unit is supplied with a three conductor electrical cord which extends...

Страница 8: ...nterior cleaned regularly CAUTION TO AVOID PERSONAL INJURY OR DAMAGE TO ELECTRICAL COMPONENTS ALWTAYS DISCONNECT UNIT FROM MAIN POWTER SOURCE BEFORE SERVICING OR CLEANING 6 1 Cabinet Surfaces Interior...

Страница 9: ...ition disconnects the condensing unit only The evaporator fan motor will be energized until the unit is disconnected from the main power source Remove the fasteners to lower the evaporator housing for...

Страница 10: ...n17 Blown19 Blown21 Blown23 Blown49 Blue16 Blue18 Blue20 Blue24 Blue50 2 1 2 1 Defrosting Heater Door Switch1 Door Switch2 Blown31 Blown33 Blown35 R2 Blown37 Blue36 Door Heater R3 Blown39 Blue38 R4 Bl...

Страница 11: ...R3 Blown39 Blue38 R4 Blown41 Blue40 Capacitor 2 1 Light Switch Blown27 Blown29 Blue34 LED1 LED2 Blown01 Blue02 Blown03 Blue04 115V 60Hz Fuse 20A Blown05 Load Switch Condenser Fan Blown07 12 15 5 6 11...

Страница 12: ...2 1 2 1 0 1 M 6 8 4 3 2 1 7 9 Dixell XR04CX Fuse 15A Relay Relay Evaporator Fan M2 3 4 Light Switch M M Blown05 Blown07 Blown09 Blown13 Blown15 Blown27 Blown29 Blue11 Blue06 Blue08 Blue12 Blue16 Blue2...

Страница 13: ...self contained display cases Wanquan agrees to repair or exchange at its option the original motor compressor unit only with a motor compressor of like or of similar design and capacity if it is shown...

Страница 14: ...or any reason 9 For costs related to shipping or handling of replacement parts 1 If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its...

Страница 15: ...below Test room climate class Dry bulb temperature C Relative humidity Dew point C Water vapour mass in dry air g kg 0 20 50 9 3 7 3 1 16 80 12 6 9 1 8 23 9 55 14 3 10 2 2 22 65 15 2 10 8 3 25 60 16 7...

Отзывы: