2. Technical
Specifications
2.1 Electrical
Specifications
2.1.1
Operating
Parameters
Parameter
Value
Unit
Skywire
UART
Baud
Rate
115200
bps
Skywire
I/O
Voltage
1.65-5.5
V
Skywire
Power
Consumption,
Active
Cell
750
mA
Normal
29
mA
Power
Saving
1.1
mA
Skywire
Input
Voltage
4
V
J1
Input
Voltage
5
V
PMOD
Input
Voltage
3.3
V
PMOD
I/O
Voltage
3.3
V
Kurumi
Input
Voltage
4
V
Temperature
Range
-40
to
+85
o
C
o
C
Dimensions
47
x
82
x
25
mm
2.2 Power
The Skywire RL78/Kurumi Adapter requires 5V and 3.3V inputs. Connector J1
accepts 5V input voltage and is used to supply power to the Skywire 4V Power
Supply. The acceptable input Voltage range for J1 is 4.8-5.2V. Do not exceed
5.5V.
The Skywire Cellular Modem will regularly consume high amounts of current
(~750 mA) from the adapters power supply. It is recommended to have 1A of
available
source
current
available
for
the
adapter
board.
PN
30018
rev
2
©
NimbeLink
Corp.
2017.
All
rights
reserved.
5