Service time setting.
Bridges 3 and 5 to change service interval.
With the temperature adjustment knob100 to
600 hours.
Change to hotwater mode to set new setting.
Change temperature display.
When 1 is on the temp. Is shown in Fahrenheit
(NB: it’s not possible to cancel by-pass time
when temp. display is set on Fahrenheit).
Cancel by-pass time
Factory setting without
hour display.
Hour display setting.
Determine the soot rating with a soot pump (1)
and soot rating reference scale. The figure
should not exceed "1". Otherwise, open the air
flap (Fig.G.07) a little and repeat the measure-
ment. Repeat the procedure until the specified
value is obtained.
Fig.G.17: Soot raiting
Fig.G.19: Service settings.
Burner settings.
The CO2 content in the exhaust, the intake
and exhaust temperature are determined. This
can be done with conventional meters or, as in
Fig. G.08, with an electronic meter like the
TESTO 327 (4), which measures and displays
all relevant data.
If the measured value is too low, close the air
flap (Fig.G.06) a little and check the soot rating
and Co2 content again.
Fig.G.18: Burner measurements.
Содержание NEPTUNE 5 FA
Страница 1: ...Service Manual NEPTUNE 5 FA NEPTUNE 5 FA_EN_Ver 2 0_25 11 ...
Страница 54: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 54 ...
Страница 55: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 55 ...
Страница 56: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 56 ...
Страница 57: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 57 ...
Страница 58: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 58 ...
Страница 59: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 59 ...
Страница 60: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 60 ...
Страница 61: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 61 ...
Страница 62: ...62 NEPTUNE 5 FA_EN_Ver 2 0_25 11 Notes ...
Страница 63: ...NEPTUNE 5 FA_EN_Ver 2 0_25 11 63 ...