background image

4  

Nilfisk 
ALTO                        

A

 

Safety Issues. 

Observe national safety 
directives and regulations 
for the electrical engineer-

ing 
trade, in particular: 
 
IEC 60335-2-69 
EN 60335-2-69 
 
DIN VDE 105 part 1: 
operation of electrical 
power installations. 
 
DIN VDE 0701/0702: 
repair, modification and 
testing of electrical installa-

tions. 
 
Before starting the equip-

ment, 
be sure to read the 
accompanying service 
manual, and keep it close 
as ready reference. 
 
The equipment should 
only be used by persons 
who have been instructed 
in its use and are author-

ized to do so.

 

Repairs should only be 
made by someone who 
has received proper 
instructions for the job 
or who is a qualified   elec-

trician.

 

For your own safety.

 

ESD (electrostatic discharge) 
 

Observe the following ESD precautions before any 
repair of or near electronic parts: 
 
• Touch the protective conductor to discharge your own body. 
• Possibly wear an anti-static wrist strap. 
• Use a conducting floor or tabletop. 
• Never touch a circuit board or electronic components, 
always hold them by the plastic or insulation. 
• Transport electronic parts in conductive packaging (e.g. special ESD packages).

 

Содержание ATTIX 30 M

Страница 1: ...Repair manual ATTIX BASIC ATTIX 30 01 PC ATTIX 30 11 PC ATTIX 30 21 PC ATTIX 40 01 PC INOX ATTIX 40 21 PC INOX ATTIX 50 01 PC ATTIX 50 21 PC Wet Dry Vacuums ...

Страница 2: ...2 2 Nilfisk ALTO Index A Saftey Issues 3 4 B Technical data 5 C Construction 6 8 D Function 9 10 E Trouble shooting 11 15 F Spare parts 16 20 G Diagram 21 22 H Tools 23 ...

Страница 3: ...ll tell you about any technical modifica tions made after publication of this repair manual Technical information sheets are a supplement to the spare parts list until a follow on publication Repair manuals and technical information sheets should be available at the site where repairs are carried out Further repair manuals of the Attix series may be necessary for repairs to the equipment It is not...

Страница 4: ...y be used by persons who have been instructed in its use and are author ized to do so Repairs should only be made by someone who has received proper instructions for the job or who is a qualified elec trician For your own safety ESD electrostatic discharge Observe the following ESD precautions before any repair of or near electronic parts Touch the protective conductor to discharge your own body P...

Страница 5: ...nsumption PIEC W 1200 Connected load for applica tions socket W 2400 2400 2400 2400 Total connected load W 1200 3600 1200 3600 1200 3600 Power cord lenght m 7 5 Power cord type H05RR F2X0 75X8 05 H05RR F 3G1 5X8 2 EU Protection class II I Protection category IPX4 RFI suppression EN 55014 1 Air volume flow max l min 3700 Static wate lift max mbar 250 Sound pressure level at 1m EN 60704 1 62 Noise l...

Страница 6: ...truction 1 2 3 1 Push and clean bottom 2 Outlet socket 3 On Of switch Attix 30 01 Basic Attix 30 01 PC Attix 40 01 PC Attix 50 01 PC Attix 30 11 PC Attix 30 21 PC Attix 40 21 PC Attix 50 21 PC Attix 50 Attix 30 Attix 40 Inox ...

Страница 7: ...7 7 Nilfisk ALTO C Construction Connection load for applications Socket Air guide Electronic board Suction motor Air flap Motor gasket ...

Страница 8: ...k ALTO C Construction Attix 30 01 Basic Attix 30 01 PC Attix 40 01 PC Attix 50 01 PC With soft start Electrical components Attix 30 21 PC Attix 40 21 PC Attix 50 21 PC With soft start and aut start stop for tools ...

Страница 9: ...n head an air flap is opened in the carrier plate which allows air to flow into the inside of the filter 3 The air flows through the filter fleece from the inside to the outside The negative pressure inside the dirt tank is reduced very quickly and the tank wall relieved of pressure Cleaning is always carried out for a short time mainly by relieving the tank wall in short bursts The dirt adhered t...

Страница 10: ... ately Auto The turbine waits for an elec tric tool to be switched on at the socket Speed control Speed control has been integrated into the manual and automatic modes Settings on the switch range are possible from 45 to 135 Advantages Optimum adjustment of the suction power to suit the application Increase in the ser vice life of the turbine Reduction in noise emis sion Energy savings Automatic s...

Страница 11: ...tivated 5 Isolate component from the electricity supply 6 Remove the two motor cables from the circuit board and the switch 7 Connect test lamp 302000764 8 Apply mains voltage 9 Test Motor lamp slowly star it to light up soft star t Set switch to minimum speed The brightness of the lamp becomes less Checking electronics of automatic starter with speed control in AUTO mode Motor Tool 302000764 Moto...

Страница 12: ...ly 6 Remove the two motor cables from the circuit board and the switch 7 Connect test lamp 302000764 8 Test Green LED lights up 5 V OK Red LED lights up motor is activated Motor test lamp is off 302000764 Plug Electrical tool test lamp into the socket 302000765 Electrical tool test lamp lights up immediately Motor test lamp slowly starts to light up soft start Set switch to minimum speed Checking ...

Страница 13: ...ord plugged in Switch operated Motor working Power at the switch Check mains plug and power cord replace if necessary Power at the motor Check switch replace if necessary Check motor replace is necessary Check safety requirements Yes Yes Yes Yes No No No Motor is not working ...

Страница 14: ...ower at the motor Power at the switch Check mains plug and power cord replace if necessary Power at start unit Check switch replace if necessary Replace start up unit Check safety requirements Motor working Check motor replace is necessary Yes Yes Yes Yes No No No No Motor not working with switch set to 1 ...

Страница 15: ...ugged into socket Power at the motor Power at the switch Check mains plug and power cord replace if necessary Power at start up unit and socket Check switch replace if necessary Replace start up unit Check safety requirements Motor working Check motor replace is necessary Yes Yes Yes Yes No No No No Motor is not working with switch set to Auto ...

Страница 16: ...16 16 Nilfisk ALTO F Spare parts Attix 30 40 50 ...

Страница 17: ...17 17 Nilfisk ALTO F Spare parts Attix 30 40 50 ...

Страница 18: ...18 18 Nilfisk ALTO F Spare parts Attix 30 40 50 ...

Страница 19: ...19 19 Nilfisk ALTO F Spare parts Attix 30 Attix 50 ...

Страница 20: ...20 20 Nilfisk ALTO F Spare parts Attix 40 Inox ...

Страница 21: ...21 21 Nilfisk ALTO G Diagram Attix Basic 30 01 ...

Страница 22: ...22 22 Nilfisk ALTO G Diagram Attix 30 01 PC 30 11 PC 30 21 PC Attix 40 01 PC 40 21 PC Attix 50 01 PC 50 21 PC ...

Страница 23: ...23 23 Nilfisk ALTO H Tools 302000764 302000765 Lamp holder E 27 60 W Alto nr 302000764 Lamp holder E 27 60 W Alto nr 302000765 ...

Отзывы: