56041481
FRONT OF MACHINE
BACK OF MACHINE
INSTALL BATTERIES ACCORDING
TO DIAGRAM BELOW. OBSERVE
CORRECT
POLARITY
AT
ALL
CONNECTIONS.
WARNING
THIS IS A 36VDC SYSTEM. USE
ONLY THE CHARGER PROVIDED
WITH THE UNIT TO RECHARGE
BATTERIES.
1 B
A
TTER
Y
BATTERY
PLUG
BATTERY
PLUG
3x2 B
A
TTERIES
244 Ah @ 20
FRONT OF MACHINE
BACK OF MACHINE
INSTALL BATTERIES ACCORDING
TO DIAGRAM BELOW. OBSERVE
CORRECT
POLARITY
AT
ALL
CONNECTIONS.
WARNING
THIS IS A 36VDC SYSTEM. USE
ONLY THE CHARGER PROVIDED
WITH THE UNIT TO RECHARGE
BATTERIES.
2 BATTERY
BATTERY
PLUG
PRELIMINARY OPERATIONS
2
- If the batteries are installed but not filled with acid
solution they must be filled with a solution of
sulphuric acid (density not lower than 1.270 Kg when
at 25°C) according to the instructions specified below
and in the Battery User Manual.
BATTERY FILLING UP WITH ACID SOLUTION
Warning: the battery acid is corrosive; if it comes in
contact with the skin or eyes rinse thoroughly with
water and consult a physician.
The batteries must be filled in a well ventilated area.
Fill every battery cell with acid; the right level is
specified in the Battery User Manual.
After one hour fill up with acid, if necessary.
Let batteries rest for a further hour; then proceed with
a recharge according to the instructions specified in the
Battery User Manual and in the MAINTENANCE
paragraph. During the recharge the battery caps must
be open.
WARNING: before starting the recharge the battery
connector must be disconnected from the machine.
After the recharge close all the cell caps and clean the
top of the battery from any acid remains.