56041481
MAINTENANCE
BATTERIES: CONTROL AND RECHARGE
Make a frequent check of the electrolyte level inside
every battery cell. The battery compartment is under
the operator seat; lift the lid and open the caps of all
the battery cells: when necessary fill up the cells with
distilled water.
Warning
: On the version with gasoline engine the
battery level check must be done every week.
The proper electrolyte level is specified in the Manual
for use and maintenance of the battery.
After filling close all the cell caps and clean the top of
the battery from any acid remains.
Warning
: the battery acid is corrosive; if it comes in
contact with the skin or eyes rinse thoroughly with
water and consult a physician.
When necessary proceed with a recharge of the battery
according to the following instructions and taking also
into account what is specified in the Battery User
Manual:
- switch the machine Off and remove the master key.
Warning: before starting the recharge the battery
connector must be disconnected from the machine.
- the recharge must be done in a well ventilated area
- open all the cell caps
- connect the battery connector to the battery charger
connector
- connect the battery charger cable to the mains (please
check that the voltage and frequency of the mains
correspond to the data of the charger)
At the end of the recharge disconnect the battery from
the charger and fit the battery connector to the
machine. Close all the cell caps and clean the top of the
battery from any acid remains.
21