ENGLISH
INSTRUCTIONS FOR USE
20
SC2000 - 9100000383
01/2015
SUPER USER KEY (yellow)
The Super User (yellow) key allows you to check some additional information on some machine operating parameters and to adjust
others to your specific requirements.
Main Screen (E, Fig. 7)
1.
Insert the Super User (yellow) key in place of the operator
(grey) key to access the main screen of the multifunction
display (51).
2.
Press push-button (A) to change the machine settings (see
Machine Settings Screen section).
3.
Press push-button (B) to check for any stored machine
alarms (see Alarms Log Screen section).
4.
Press push-button (C) to check the machine’s hours of
operation (see Operating Time Counter Screen section).
5.
Press push-button (D) to exit service mode and return to
operator mode.
Machine Settings Screen (F, Fig. 7)
This function allows you to customise some parameters
described in the following table of modifiable parameters.
1.
Press push-button (B) to increase the value of the current
parameter.
Press push-button (C) to decrease the value of the current
parameter.
2. Press push-button (A) to move to the next parameter.
3.
To return to the main screen, press and hold the push-
button (A) for more than 1 second.
E
F
A
B
C
D
Figure 7
P100869
TABLE OF MODIFIABLE PARAMETERS
Values
Code
Description
Minimum
Factory Setting
Maximum
CHM1
Detergent concentration level 1
0.25 % (1:500)
0.25 % (1:500)
3 % (1:33)
CHM2
Detergent concentration level 2
0.25 % (1:500)
0.80 % (1:125)
3 % (1:33)
P1/P3
Level 1 solution flow rate in relation to level 3
(flow rate as function of speed)
0 %
25 %
100 %
P2/P3
Level 2 solution flow rate in relation to level 3
(flow rate as function of speed)
0 %
50 %
100 %
P3
Level 3 solution flow rate (flow rate as function of speed)
1.0 cl/m
3.0 cl/m
5.0 cl/m
P4
Enablement of level 4 (2.8 l/min regardless of speed)
OFF
OFF
ON
SPT
EcoFlex™ function timer
0 (disabled)
60 sec.
300 sec.
XPRES
Brush deck extra pressure enablement
OFF
ON
ON
FVMAX
Maximum forward speed
10 %
100 %
100 %
RVMAX
Maximum reverse speed
10 %
40 %
50 %
WSMIN
Minimum working speed
10 %
25 %
100 %
WSMAX
Maximum working speed
10 %
100 %
100 %
BRK
Electromagnetic brake activation delay
0 sec.
1 sec.
5 sec.
BAT
(**)
Installed battery type (see table)
0
1
5
TOFF
Automatic shut-off time
0 (disabled)
300 sec.
600 sec.
BRGH
Display contrast
5
15
50
VRID
Silent mode setting
1
1
5
RPM
(*)
Reduced brush rpm activation threshold
5
9
20
RESET
Restore factory settings for all parameters
OFF
OFF
ON
(*)
Increase the value of this parameter to reduce the brush motor speed in a wider range of applications and vice versa.