3.  Pull forward the spray lance or any other accessory to 

ensure correct mounting before starting the machine.

NOTE! 

Clean nipple of any impurities each time the spray 

lance has been dismounted.

B.1.3  Application of detergents (external, only 160 

bar machines)

If you want to apply detergents or disinfectants these should 
be dosed to the water through an injector. In conjunction 
with the injector it may be ad van ta geous to use a wall rack 
on which spray lances, 2 pcs. of 25 l containers as well as 
10 m high pressure hose can be placed.

Below you will fi nd various types of outlet points with injectors.

1.  Outlet point with detachable injector

To be attached to the quick coupling of the high pressure cock.

To be used for dosing of low-foaming detergents or disin-
fectants.

Dosage 1-8%.

2.  Outlet point with detachable foam injector

To be attached to the quick coupling of the high pressure cock.

To be used in conjunction with foam lance for application of 
high-foaming de ter gents or disinfectants.

Dosage 1-5%.

3.  Outlet point with cleaning trolley and foam injector

To be attached to the quick coupling of the high pressure cock.

To be used in the same way as “Outlet point with detachable 
foam injector”.

Makes it possible to place 4 spray lances, 2 pcs. of 25 l 
containers as well as 20 m high pressure hose.

B.2  Start

B.2.1  First activation of the main switch with con-

nected main power supply

By turning the main switch to ON position the control system 
will start the self-validation procedure and start up the display, 
please note that there is a start-up delay on the display.

In the self-validation mode, the water tank is fi lled up with 
water and all the protection circuits are checked. The green 
circle around the start button will fl ash.

If the water tank is not fi lled up in 4 minutes, the system will 
stop and the water supply needs to be checked. The water 
level in the water tank is shown on the display.

When the water tank is fi lled with water and the system is 
ready to start, the green circle will stop fl ashing.

B.2.2  Start/stop

Press  the  start  button  on  the  display  (FIG.1  #3)  and  the 
green circle around the button will light up.

Press  the  stop  button  on  the  display  (FIG.1  #4)  and  the 

machine will stop and turn the green circle off .

When the start button is activated the machine will start up 
Motor Pump Unit (MPU) to reach the wanted pressure, it 
is shown on the display which MPU that is activated, the 
specifi c  MPU-symbol  (FIG.1  #8)  lights  up  green.  MPU´s 
will automatically be turned on/off  when output water fl ow 
is changed, and the frequency inverter will adjust the line 
pressure to the selected pressure. Actual line pressure is 
shown on the display (FIG.1 #2).

B.2.3  Line pressure adjustment

The line pressure from the machine can be adjusted. To adjust 
the pressure, push on the pressure value by the pressure 
adjustment tab on the display (FIG.1 #13) for 20 sec. then 
use the +/- tab to adjust to the wanted pressure and press 
OK to save the value or press cancel to undo the change.  
NOTE: If the pressure change is permanent, adjustment of 
the mechanic bypass valve is necessary. 

B.2.4  Water tank

The water level will automatically be maintained by the con-
trol system, the inlet valve symbol will light up blue on the 
display when the inlet valve is activated. The actual water 
temperature is shown on the display (FIG.1 #1).

If the Cold/Hot option is mounted on the machine the water 
temperature is adjusted to the selected temperature, two 
valves are shown on the display, one for Cold inlet water 
and one for Hot inlet water, when the Cold valve is activated 
it lights up blue and when the hot valve is activated it lights 
up red. To adjust the temperature, push on the temperature 
value  by  the  temperature  adjustment  tab  on  the  display 
(FIG.1 #12) for 10 sec. and use the +/- tab to adjust to the 
wanted temperature and press OK to save the value or press 
cancel to undo the change.  

B.2.5  Bypass system

When the output water fl ow is reduced, the bypass system 
will activate. When the bypass system is activated, the water 
will return to the water tank, the actually volume is shown 
on the display (FIG.1 #14), the bar light up and show the 
water volume, if 1/3 of the bar is blue on a 6 MPU machine, 
the water from two MPU´s is returning to the water tank.

If more than one pump is active all the redundant pumps 
will stop after 8 seconds, if the outlet is completely closed 
the last pump will stop after 20 sec.

The machine is still active and starts up again when the line 
pressure drops below the start pressure.

B.2.6  Errors and warnings.

There are two types of failures in the control system on the 
machine:

• 

Error: 

Inverter error, Critical water level, All MPU deac-

tivated,  Inlet  water  fl ow  low,  low  output  pressure,  High 
temperature water tank, remote or display communication 
failure. These errors will stop the machine immediately 
because it is critical for the machine or connected systems.

• 

Warnings: 

MPU oil level low, MPU thermic high temp, 

MPU overload protection activated, abnormal water level 

Содержание SC DELTA

Страница 1: ...SC DELTA Instructions for use 107309173 C 09 2018 ...

Страница 2: ...2 SC DELTA Operating instructions 7 Bedienungsanweisungen 15 Instructions de fonctionnement 23 Instruccciones de funcionamiento 32 ...

Страница 3: ...3 SC DELTA A 1 2 3 4 5 6 Min 400 mm Min 200 mm Min 500 mm A 1 A 2 8 7 9 10 Min 1000 mm 120 mm 11 1a ...

Страница 4: ...4 SC DELTA A 3 A 6 A 4 A 1 A 5 1 A 3 1 1 1 4 BSP Inlet Outlet hose DKO 28 NUT M36x2 mm ...

Страница 5: ...5 SC DELTA B B 1 2 B 1 3 1 2 3 1 2 1 B 1 1 1 B 3 2 ...

Страница 6: ...6 SC DELTA C B 5 C 1 C 2 1 ...

Страница 7: ...cinity of the machine Max water pressure 10 bar Min water pressure 2 bar Max water inlet temp See label on machine by the water inlet See A 3 1 for dimensions On the back side of the machine there are 2 hoses attached to the water tank These are overflow hoses in case of a malfunction in the water tank The two hoses must not be blocked Ifthereisariskofrunningsandsor other impurities in the inlet wa...

Страница 8: ...ial lead in bushes are available The outlet points should be placed as close to the opera tion point as possible and so that a hose length preferably of 20 m is used It is recommended to let a service technician authorized by Nilfisk prepare the pipeline A 6 Venting Start the machine and open all high pressure cocks on the pipeline until all air has escaped Start with the remotest high pressure coc...

Страница 9: ...MPU that is activated the specific MPU symbol FIG 1 8 lights up green MPU s will automatically be turned on off when output water flow is changed and the frequency inverter will adjust the line pressure to the selected pressure Actual line pressure is shown on the display FIG 1 2 B 2 3 Line pressure adjustment Thelinepressurefromthemachinecanbeadjusted Toadjust the pressure push on the pressure value...

Страница 10: ...t pressure low limit error option Check water flow Check available pumps 3 Start machine Flash green control system in self validation mode Green machine active 4 Stop machine Reset warning error Flash red system warning Red system error Check below points MPU oil level MPU internal heat sensor MPU overload protection WBT below normal level Inverter failure Water level error MPU 5 Red actualMPU tem...

Страница 11: ... level Yellow warning water level Red Critical water level Water inlet Valves Blue Cold water inlet open Red Hot water inlet open Check water supply Check water filter Check water supply Check water filter Temp 12 Adjust water tank tempera ture Press the value 60 C for 10 sec to open the adjustment window option accessory Pressure 13 Adjust the line pressure Press the value 100 for 20 sec to open th...

Страница 12: ... machine should be started and the quick coupling cleaned of dust and sand C 1 Oil Check the oil level in the oil glas If the oil level gets too low the pump will automatically shut down and 6 will light up In the case of repeated low oil level oil waste please contact a Nilfisk service technician PROTECT THE ENVIRONMENT Waste oil and oil sludge must be removed as laid down in the instructions C 2 ...

Страница 13: ...lve of spray lance not adjusted to max pressure Nozzle partly clogged up Replace the nozzle Replace the spray lance Turnreductionvalvecompletelycounter clockwise Clean the nozzle see section C 3 Working pressure not steady Water temperature too high Insufficient water supply to pumps Air in the system Water filters clogged up Lowerthetemperatureoftheinletwater to max temperature see Technical Specific...

Страница 14: ...n carried out or attempted by other than Nilfisk trained service staff that only original accessories have been applied that the product has not been exposed to abuse such as knocks bumps or frost that the instructions in the manual have been carefully observed A warranty repair comprises the replacement of defective parts but it does not cover freight and packaging charges Besides we refer to natio...

Страница 15: ...87 48 64 95 4 kW 27 35 55 27 35 55 5 PIEC bar MPa 160 16 100 10 6 QIEC l h 4400 5800 8600 7000 9500 14500 7 Pmax bar MPa 250 25 150 15 8 Qmax l h 4500 6000 9000 7500 10000 15000 9 tmax C F 70 158 10 pmax bar MPa 10 1 11 pmin bar MPa 2 0 2 12 m 0 13 mm 970x1050x1800 14 kg 349 408 526 348 408 526 15 LPA IEC 60335 2 69 dB A 2 84 85 87 84 85 87 16 LWA IEC 60335 2 69 dB A 2 100 101 103 100 101 103 17 a...

Страница 16: ...ssion pression Min ES Presión mínima de entrada del agua 12 m EN Max dry suction height DE Max Trockensaughöhe FR Hauteur d aspiration à sec max ES Altura máxima de succión en seco 13 mm EN Dimensions LxWxH DE Masse LxBxH FR Dimensions l x p x h ES Dimen siones l x a x al 14 kg EN Weight DE Gewicht FR Poids du nettoyeur ES Peso del limpiador 15 LPA IEC 60335 2 69 dB A 2 EN Sound pressure level LPA...

Страница 17: ... Inc 1 6 6 Kita shinyokohama Kouhoku ku Yokohama 223 0059 Tel 81 45548 2571 www nilfisk com MALAYSIA Nilfisk Sdn Bhd Sd 33 Jalan KIP 10 Taman Perindustrian KIP Sri Damansara 52200 Kuala Lumpur Tel 60 3603 627 43 120 www nilfisk com MEXICO Nilfisk de Mexico S de R L de C V Pirineos 515 Int 60 70 Microparque Industrial WSantiago 76120 Queretaro Tel 52 442 427 77 00 www nilfisk com NEW ZEALAND Nilfisk Limi...

Отзывы: