High pressure
Low pressure / Detergent
5.6 Pressure
regulation
Flexopower Plus spray lance
The pressure can be regulated
on the Flexopower Plus spray
lance.
5.7 Operation
with
detergents
Application of detergents is
NOT
possible if an extension
hose is applied.
1. Fill the container with a de-
tergent.
2. Mount the Flexopower Plus
spray lance and adjust it to
low pressure (see section
5.6).
3. Adjust the dosing regulator
(10) to the re quired vol ume
of detergent (0-5%).
4. Apply the detergent from
below and up wards.
5. Let the detergent act for the
time stated on the packing of
the detergent and fl ush with
pure water.
External detergent container
1. Remove the cover with suc-
tion hose from the detergent
container.
2. Mount the cover with suction
hose on the external deter-
gent container.
The cover has a standard thread
and fi ts common detergent con-
tainers. If your container does
not have a standard thread,
detach the fi lter from the suc-
tion hose and remove the cover.
Remount the fi lter in the suction
hose.
Extra detergent hose can be
pulled out of the machine.
5.8 Regulation of pressure /
water volume
Working pressure and water
volume can be regulated on the
machine by turning the button
for regulation of pressure / wa-
ter volume (5).