background image

FORM NO. 56041431 / GW 4512, GW 6016 - 

6

AFTER USE - WET PICK UP

1

Step down on the Squeegee Raise/Lower Pedal 

(4)

 to raise the Squeegee

(Air Scoop model only).  Turn the Main Power Switch 

(1)

 OFF and unplug

the Power Cord 

(6).

2

Move the machine to a “DESIGNATED” waste water disposal site.

3

Remove the Drain Hose 

(5)

 from its hanger, direct the end of the hose to

a proper disposal area and remove the plug.  On 100V model, remove the
Power Head 

(2)

, lift out the Bucket 

(14)

, empty and rinse with warm water.

4

Remove the Power Head 

(2)

 from the Recovery Tank / Chassis 

(3)

 and

rinse the tank with warm water.

NOTE:  

Clean and inspect the Float 

(B)

 for debris or damage (Figure B).

5

Remove the Squeegee 

(9)

 or Wand and Recovery Hose 

(8) 

and rinse

them in warm water.

6

Dry out the Recovery Tank / Chassis 

(3)

, Bucket 

(14)

 on 100V model,

before re-installing the Power Head 

(2)

.

7

Wipe the machine with a damp cloth.  Check the Maintenance Schedule
and perform any required maintenance before storage.

8

Store the machine indoors in a clean, dry place.

AFTER USE - DRY PICK UP

1

Turn the Main Power Switch 

(1)

 OFF and unplug the Power Cord 

(6).

Remove the Power Head 

(2)

 from the Recovery Tank / Chassis 

(3).

2

Remove the Dry Pick-up Filter and shake out, brush off and vacuum out
for normal up keep.

3

Reinstall the Dry Pick-up Filter on the Power Head 

(2)

.

4

Empty the debris from the Recovery Tank / Chassis 

(3)

, Bucket 

(14)

 on

100V model, rinse the tank (bucket) clean and dry it out.

5

Reinstall the Power Head 

(2)

 on the Recovery Tank / Chassis 

(3)

 and

Latch 

(11)

 into place.

6

Wipe the machine with a damp cloth.  Check the Maintenance Schedule
and perform any required maintenance before storage.

7

Store the machine indoors in a clean, dry place.

LUBRICATION

Lubricate the caster swivels and the squeegee raise / lower pivot points with light
machine oil.

VACUUM MOTOR BRUSHES

Have your Advance Dealer check the carbon motor brushes once a year or after
500 operating hours.

IMPORTANT !

Motor damage resulting from failure to service the carbon brushes
is not covered under warranty.  See the Limited Warranty State-
ment.

CAUTION !

Unplug  the  Power  Cord 

(6)

  before  performing  any  machine

maintenance.

MAINTENANCE SCHEDULE

Maintenance Item

Daily

Monthly

Yearly

Clean the Recovery Tank (Bucket)

X

Clean the Power Head

X

Clean the Float

X

Clean the Squeegee

X

Clean the Dry Pick-Up Filter

X

Inspect Tank and Hoses

X

**Inspect Power Cord

X

Lubrication

X

Inspect and Clean

Vac Motor Outlet Filter

X

*Check Vacuum Motor Brushes

X

*Have  Advance  check  the  carbon  motor  brushes  once  a  year  or  after  500
operating hours.
** If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent or a similarly qualified person in order to avoid a hazard.

TECHNICAL SPECIFICATIONS (as installed and tested on unit)

GW 4512 / GW 4512 AS

GW 4512 / GW 4512 AS

Model

GW 6016 / GW 6016 AS

GW 6016 / GW 6016 AS

GW 4512

56209801 / 56209806

56209803 / 56209809

Model Number

56209802 / 56209807

56209805 / 56209813

56210000

Voltage/frequency

V/Hz

120V / 50/60Hz

220-240V / 50/60Hz

100V / 50/60Hz

Rated Power

W

800

1,100

1,200

Protection Class (electrical)

Protection grade (mec, moist, dust)

N/A

IP 34

N/A

Sound Pressure Level (at operator’s ear)

dB(A)/20

µ

Pa

75

75

75

Vibration at the Hand Controls

m/s

2

<2.5m/s

2

<2.5m/s

2

<2.5m/s

2

Содержание GW 4512

Страница 1: ...12 98 revised 10 99 Form Number 56041431 GW 4512 GW 6016 OPERATOR MANUAL Advance MODELS 56209801 56209803 56209806 56209809 56209802 56209805 56209807 56209813 56210000 ...

Страница 2: ...S DE SÉCURITÉ 3 120VAC GROUNDING INSTRUCTIONS 4 INSTRUCTIONS VISANT LA MISE À LA TERRE 120VAC 4 Introduction 5 Machine Assembly 5 Know Your Machine 5 To Pick Up Water 5 To Pick Up Dust And Dirt 5 After Use Wet Pick Up 6 After Use Dry Pick Up 6 Lubrication 6 Vacuum Motor Brushes 6 Maintenance Schedule 6 Technical Specifications 6 ...

Страница 3: ...d sharp edges or corners Do not run the appliance over the cord Keep the cord away from heated surfaces Do not unplug by pulling on the cord To unplug grasp the plug not the cord Do not handle the plug cord or appliance with wet hands Donotputanyobjectintoopenings Donotusewithanyopeningblocked keepfreeofdust lint hair andanythingthatmayreduce air flow Keep loose clothing hair fingers and all parts...

Страница 4: ...il sur le cordon Gardez le cordon à l écart de toutes surfaces chaudes Ne débranchez pas l appareil en tirant sur le cordon Pour débrancher empoignez la prise pas le cordon Ne touchez pas à la prise au cordon ou à l appareil avec des mains mouillées Ne placez aucun objet dans les ouvertures Ne l utilisez pas quand une des ouvertures est bloquée gardez les à l abri de la poussière de la charpie des...

Страница 5: ...C Cet appareil doit être mis à la terre En cas de défaillance ou de panne éventuelles la mise a la terre fournit au courant un chemin de moindre résistance qui réduit le risque de choc électrique Cet appareil est pourvu d un cordon muni d un conducteur de terre et d une fiche avec broche de terre La fiche doit être branchée dans une prise appropriee correctement installée et mise à la terre confor...

Страница 6: ...surethattheMainPowerSwitch 1 isinthe OFF position then plug the Power Cord 6 into a wall outlet 3 If you have an Air Scoop model re attach the Squeegee 9 and the Recovery Hose 8 If you have a non Air Scoop model re attach the recovery hose 4 Connect the other end of the Recovery Hose 8 to the Squeegee 9 or wand and wet pick up tool Accessory hoses wands and other attachments are available from you...

Страница 7: ... machine with a damp cloth Check the Maintenance Schedule and perform any required maintenance before storage 7 Store the machine indoors in a clean dry place LUBRICATION Lubricatethecasterswivelsandthesqueegeeraise lowerpivotpointswithlight machine oil VACUUM MOTOR BRUSHES Have your Advance Dealer check the carbon motor brushes once a year or after 500 operating hours IMPORTANT Motordamageresulti...

Отзывы: