CONTROLLER ERROR CODES
For all error codes:
Turn key switch of
f & then back on. If error persists consult chart below and/or service manual.
Error
Code
Description
Possible Cause
Corrective
Action
1
Control fault
Control failure
Turn key switch of
f & back on. If problem persists consult service manual.
2
Critical control fault
Control failure
Turn key switch of
f & back on. If problem persists consult service manual.
3
Drive system fault
Tripped wheel drive circuit breaker
Reset circuit breaker
Throttle not in neutral (HPD fault)
Verify that throttle is in neutral before turning key on.
Adjust throttle mecha-
nism.
Wheel drive system problem
Consult service manual.
4
Scrub deck lift actuator overload
Scrub deck obstruction / binding
Remove obstruction. Lubricate mechanism.
Defective actuator motor
Consult service manual.
5
Scrub deck lift actuator severe overload
See error code 4
6
Scrub deck lift actuator circuit open / output fault
Bad electrical connection
Check all conections to actuator motor
.
Defective actuator motor
Consult service manual.
Control failure
Consult service manual.
7
Scrub motor overload
Scrub motor obstruction
Remove obstruction. Check to see that motors rotate freely
.
Defective scrub motor
Consult service manual.
8
Scrub motor severe overload
See error code 7
9
Scrub motor circuit open
Bad electrical connection
Check all conections to scrub motors.
Defective scrub motor(s)
Consult service manual.
Control failure
Consult service manual.
10
Scrub motor contactor contacts shorted
Contactor failure
Consult service manual.
11
Not used
12
Scrub motor contactor coil overload
Contactor failure
Consult service manual.
Coil suppression diode failure
Consult service manual.
13
Scrub motor contactor coil severe overload
See error code 12
14
Scrub motor contactor coil circuit open / output fault
Bad electrical connection
Check all connections to scrub motor contactor
.
Contactor failure
Consult service manual.
Control failure
Consult service manual.
15
Not used
16
Not used
17
Scrub motor cable thermistor fault
Machine temperature out of range
This error will occur if the machine temperature is below 3
2*F or above 185*F
.
This error will not prevent operation of the machine. Scrub pressure may be
af
fected.
Thermistor failure
Consult service manual.
18
Squeegee lift actuator overload
Squeegee obstruction / binding
Remove obstruction. Lubricate mechanism.
Defective actuator motor
Consult service manual.
19
Squeegee lift actuator severe overload
See error code 18
20
Squeegee lift actuator circuit open / output fault
Bad electrical connection
Check all conections to actuator motor
.
Defective actuator motor
Consult service manual.
Control failure
Consult service manual.
21
Not used
22
Not used
23
Not used