ENGLISH / B-19
FORM NO. - 56041703 - BA 625, BA 725, BA 825 -
B-19
SERVICING THE RECOVERY TANK SWITCH(ES)
If the recovery tank
fl
oat switch(es) become dirty it can impair their proper operation. A dirty vacuum shut off switch can cause the vacuum motor to
not function at all or to not shut off when the tank is full. Dirty extended scrub system switches can prevent the optional extended scrub system from
functioning properly.
If daily rinsing of the recovery tank does not suf
fi
ce to keep the switches clean you may need to disassemble them for cleaning. It is very important
that they be reassembled correctly in order to function. See Figure 6 for the correct orientation of the switch
fl
oat arms.
Refer to the service manual for detailed disassembly and cleaning instructions.
FIGURE 6
A - (Open) Vacuum Off
B - (Closed) Vacuum On
C - (Closed) Vacuum Off
D - (Open) Vacuum On
Float on TOP.
Original Orientation
Normally Closed
Current Orientation
Normally Open
Float on BOTTOM.
See above for
fl
oat orientation.
Factory installed Vacuum Shut-Off Switch.
Optional Extended Scrub Start Switch.
Float on BOTTOM.
Optional Extended Scrub Stop Switch.
Float on BOTTOM.
Float should move up & down freely.
ON
ON
OFF
revised 10/08
Содержание BA 625
Страница 5: ...TÜRKÇE A 5 FORM NO 56041703 BA 625 BA 725 BA 825 A 5 ...
Страница 15: ...TÜRKÇE A 15 FORM NO 56041703 BA 625 BA 725 BA 825 A 15 30 13 15 22 28 2 12 A B I D H G E 5 GG FF ...
Страница 23: ......
Страница 27: ...ENGLISH B 5 FORM NO 56041703 BA 625 BA 725 BA 825 B 5 revised 1 07 ...
Страница 37: ...ENGLISH B 15 FORM NO 56041703 BA 625 BA 725 BA 825 B 15 30 13 15 22 28 2 12 A B I D H G E 5 GG FF revised 6 05 ...
Страница 45: ......
Страница 46: ......