3/2019
A - 13
56091217 - SC901 ST
ENGLISH - A
INSTRUCTIONS FOR USE
FILLING THE SOLUTION TANK
Fill the solution tan k with a maximum of 30 gallons (113.5 Liters) of cleaning solution. Do not
fi
ll the solution tank above 7.5 cm (3 inches) from the
bottom of the Solution Fill
(1)
. The solution should be a mixture of water and the proper cleaning chemical for the job. Always follow the dilution
instructions on the chemical container label.
NOTE:
EcoFlex machines can either be used conventionally with detergent mixed in the tank or the
detergent dispensing system can be used.
CAUTION!
Use only low-foaming, non-
fl
ammable liquid detergents intended for machine application. Water temperature should not exceed 130
degrees Fahrenheit (54.4 degrees Celsius)
SQUEEGEE INSTALLATION
1
See Figure 4.
Ensure the Squeegee Seal
(39)
is free from debris and installed in the Squeegee Mount Bracket
(M)
.
2
Slide the Squeegee Assembly
(12)
onto the Squeegee Mount Bracket
(M)
and tighten the Squeegee Mount Thumb Nuts
(33)
.
IMPORTANT!: HAND TIGHTEN THE SQUEEGEE THUMB NUTS ONLY, DO NOT USE TOOLS.
3
Connect the Recovery Hose
(34)
to the squeegee inlet.
4
The Squeegee Mount Bracket
(M)
has a factory set position so that the rear squeegee blade touches the
fl
oor evenly across its entire width
and is bent over slightly as shown.
NOTE:
A service technician can adjust the Turnbuckle Assembly
(N)
to change the squeegee angle if needed.
FIGURE 4
M
N
1
33
33
12
34
39
39