A-14 / ENGLISH
A-14
- 56041640 - Adhancer
™
/ BA 855 TRIO EDS
™
WET SCRUBBING
WARNING!
Be sure you understand the operator controls and their functions. While on ramps or inclines, avoid sudden stops when loaded. Avoid
abrupt sharp turns. Use low speed down hills. Clean only while ascending (driving up) the ramp.
1
See Figure 4.
Follow the instructions in the Preparing the Machine For Use section of this manual.
2
Turn the Master Key Switch
(A)
ON (I). This will display the control panel indicator lights, reference the Battery Indicator and Hour Meter on the Display
(D)
.
3
To transport the machine to the work area, push the Drive Paddle
(34)
forward to go forward or pull the Drive Paddle
(34)
backward to move the machine in
reverse. Vary the pressure on the Drive Paddle
(34)
to obtain the desired speed.
NOTE:
Speed Control Knob
(31)
is used to control the maximum speed in either forward or reverse.
4
Press and hold the Solution Switch
(B)
for 5 seconds to pre-wet the
fl
oor.
NOTE:
This must be done prior to pressing the Scrub ON Switch
(I)
.
5
Press the Scrub ON Switch
(I)
once for Scrub mode. The scrub deck will be lowered to the
fl
oor. Both the solution system and detergent system have 1
fl
ow
rate.
NOTE:
There is a solution
fl
ow rate over-ride function if you wish to increase solution
fl
ow. Hold the Solution Switch
(B)
for 5 seconds (solution indicator
will start
fl
ashing) and then let go. You then have 3 seconds to press the Solution Switch
(B)
again to increase to a Heavy Flow. The Solution Flow Rate
Indicator
(D1)
shows the desired rate (Regular or Heavy see Control Panel). After the time delay (solution indicator no longer
fl
ashing), pressing the solution
switch will turn the solution
fl
ow between OFF and ON (ON at desired
fl
ow rate). When the key switch is turned off and back on, the solution
fl
ow rate reverts
to regular scrub.
NOTE:
The solution, vacuum and detergent systems are automatically activated when the Scrub ON Switch
(I)
is pressed. No further action is required other
than lowering the squeegee
(17)
. Any individual system can be turned OFF or back ON by simply pressing its switch at any time during scrubbing.
6
Lower the squeegee with the Squeegee Raise / Lower Lever
(17)
.
7
When the Drive Paddle
(34)
is in the neutral position, the scrub, vacuum, solution and detergent systems are enabled but not running. Grip the Operator Control
Handle
(2)
and push the Drive Paddle
(34)
forward to start the scrub, vacuum, solution and detergent, and to move the machine forward. For best results, move
the machine at a slow walking speed. Press the Solution Switch
(B)
once to turn OFF while making sharp turns. Pull the Drive Paddle
(34)
backward to move
the machine in reverse. The brushes will run while moving the machine in reverse, but solution and detergent will not be dispensed.
CAUTION!
To avoid damaging the
fl
oor, keep the machine moving while the brushes are turning.
8
For extremely dirty
fl
oors, a one-pass scrubbing operation may not be satisfactory and a “double-scrub” operation may be required. This operation is the same
as a one-pass scrubbing except on the
fi
rst pass the squeegee is in the up position. This allows the cleaning solution to remain on the
fl
oor to work longer. The
fi
nal pass is made over the same area, with the squeegee lowered to pick up the accumulated solution.
9
The recovery tank has an automatic shut-off switch that turns ALL systems OFF except the drive system when the recovery tank is full. When this switch is
activated, the recovery tank must be emptied. The machine will not pick up water or scrub with the switch activated.
NOTE:
All other indicators vanish and a Recovery Tank FULL Indicator
(D7)
turns on in the Display Panel when the switch is activated.
10 When the operator wants to stop scrubbing or the recovery tank is full, press the Scrub OFF Switch
(H)
once. This will automatically stop the scrub brushes
and solution
fl
ow and the scrub deck will raise UP.
NOTE:
The vacuum will stop after a 10 second delay. This is to allow any remaining water to be picked up
without turning the vacuum back on.
11 Raise the squeegee and drive the machine to a designated wastewater “DISPOSAL SITE” and empty the recovery tank. To empty, pull the Recovery Tank Drain
Hose
(27)
from its hanger and open the cap (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled
fl
ow of waste water). The
Recovery Tank Drain Hose
(27)
can be squeezed to regulate the
fl
ow. Re
fi
ll the solution tank and continue scrubbing.
NOTE:
Make sure the Recovery Tank Cover
(5)
and the Recovery Tank Drain Hose
(27)
cap is properly seated or the machine will not pick-up water correctly. When
the batteries require recharging the Battery LOW Indicator
(D8)
will come on and the vacuum motor will shut off after 30 seconds. Transport the machine to a service
area and recharge the batteries according to the instructions in the Battery section of this manual.
WET VACUUMING
Fit the machine with optional attachments for wet vacuuming.
1
Disconnect the Recovery Hose
(19)
from the Squeegee
(13).
2
Attach suitable wet pick-up tools to the hose (Available from Nil
fi
sk-Advance).
3
Turn the Master Key Switch
(A)
ON.
4
Press the Wand Switch
(E)
once to turn ON the vacuum motor.
SERVICE NOTE: Refer to the service manual for detailed functional descriptions of all controls and optional programmability.
Содержание Adhancer BA 855 TRIO EDS
Страница 15: ...ENGLISH A 15 Adhancer BA 855 TRIO EDS 56041640 A 15 WET SCRUBBING FIGURE 4 ...
Страница 34: ...B 14 ESPAÑOL B 14 56041640 Adhancer BA 855 TRIO EDS FREGADO EN HÚMEDO FIGURA 4 ...
Страница 41: ......
Страница 43: ......