![Nilfisk-Advance 56507000 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/nilfisk-advance/56507000/56507000_instructions-for-use-manual_1692977023.webp)
ENGLISH / A-23
FORM NO. 56041656 - Exterra™ / SR 1900 -
A-23
TROUBLESHOOTING
If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Nil
fi
sk-Advance Service
Center immediately for service.
TRIPPING THE CIRCUIT BREAKERS
The circuit breakers are located on the Circuit Breaker Panel
(H)
, they protect electrical circuits and motors from damage due to overload
conditions. If a circuit breaker trips, try to determine the cause.
Main Circuit Breaker (CB1 / 70 Amp) Possible cause may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
Headlight Circuit Breaker (CB2 / 20 Amp) Possible cause may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
Starter Motor Circuit Breaker (CB3 / 15 Amp) Possible causes may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
Accessory Circuit Circuit Breaker (CB4 / 20 Amp) Possible cause may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
Ignition Circuit Circuit Breaker (CB5 / 10 Amp) Possible cause may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
Turn Signal Circuit Breaker (CB6 / 15 Amp) Possible cause may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
Mister Circuit Breaker (CB7 / 10 Amp) Possible cause may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
HVAC Circuit Breaker (CB8 / 10 Amp) Possible cause may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
HVAC Circuit Breaker (CB9 / 40 Amp) Possible cause may be:
1
Electrical short circuit or overload (have your Nil
fi
sk-Advance Service Center or quali
fi
ed electrician check the machine)
Once the problem has been corrected, push the button in to reset the circuit breaker. If the button does not stay in, wait 5 minutes and try again.
If the circuit breaker trips repeatedly, call your Nil
fi
sk-Advance Service Center for service.
Содержание 56507000
Страница 7: ...ENGLISH A 7 FORM NO 56041656 Exterra SR 1900 A 7 3 CYLINDER MODELS 4 CYLINDER MODELS ...
Страница 17: ...ENGLISH A 17 FORM NO 56041656 Exterra SR 1900 A 17 FIGURE 1 ...
Страница 29: ...ESPAÑOL B 5 FORM NO 56041656 Exterra SR 1900 B 5 ...
Страница 31: ...ESPAÑOL B 7 FORM NO 56041656 Exterra SR 1900 B 7 MODELOS DE 3 CILINDROS MODELOS DE 4 CILINDROS ...
Страница 41: ...ESPAÑOL B 17 FORM NO 56041656 Exterra SR 1900 B 17 FIGURA 1 ...
Страница 50: ......
Страница 51: ......
Страница 52: ...www nilfisk advance com 2007 ...