62 - FORM NO. 56043089 / AquaRide
™
/ BRX 700
ELECTRICAL SYSTEM
Maintenance mode Switch (D):
This switch is used to control the output to the scrub deck lift actuator. Pressing and releasing this switch will cycle the actuator output through 4
states. These are:
1 - output off, direction = up
2 - output on, direction = down
3 - output off, direction = down
4 - output on, direction = up
When the output is in state 1, the actuator output is turned off. The maintenance mode indicator should be off. If the indicator is fl ashing green, this
indicates that the control is sensing current fl ow through the actuator (shorted output driver, control error). If the maintenance mode switch was the
last switch pressed, it is possible to momentarily activate the actuator output using the horn switch. This can be used to jog the actuator to allow
precise positioning of the actuator. NOTE: the actuator can only move in this situation if it is not at its up limit.
When the output is in state 2, the actuator output is turned on. The maintenance mode indicator should be green or fl ashing green. The indicator
will be a steady green if the control senses current fl ow through the actuator. It will fl ash green if no actuator current fl ow is sensed (actuator at
limit, open circuit, open output driver). The horn switch has no effect in this state.
When the output is in state 3, the actuator output is turned off. The maintenance mode indicator should be off. If the indicator is fl ashing green, this
indicates that the control is sensing current fl ow through the actuator (shorted output driver, control error). If the maintenance mode switch was the
last switch pressed, it is possible to momentarily activate the actuator output using the horn switch. This can be used to jog the actuator to allow
precise positioning of the actuator. NOTE: the actuator can only move in this situation if it is not at its down limit.
When the output is in state 4, the actuator output is turned on. The maintenance mode indicator should be green or fl ashing green. The indicator
will be a steady green if the control senses current fl ow through the actuator. It will fl ash green if no actuator current fl ow is sensed (actuator at
limit, open circuit, open output driver). The horn switch has no effect in this state.
Restore Mode Switch (F):
This switch does not control any output functions. Pressing this switch will illuminate the restore mode indicator.
Vacuum Switch (O):
This switch is used to toggle the state of the vacuum motor. Pressing and releasing this switch will alternately turn the vacuum motor on and off.
The indicator (P) provides the following status information:
Off - Vacuum motor output is off and there is no vacuum motor current sensed.
Steady Green - Vacuum output is on and there is normal vacuum motor current sensed.
Brief On Green Flash - Vacuum motor output is off and vacuum motor current is being sensed (abnormal condition).
Brief Off Green Flash - Vacuum motor output is on and vacuum motor current is not being sensed (abnormal condition).
Flashing Red – Vacuum motor overload has occurred.
SERVICE TEST MODE (CONTINUED)
Содержание 56314019
Страница 7: ...FORM NO 56043089 AquaRide BRX 700 5 SPECIFICATIONS ...
Страница 25: ...WHEEL DRIVE SYSTEM FORM NO 56043089 AquaRide BRX 700 23 FIGURE 6 A FRONT D F G E L J K I H N O Q P M R ...
Страница 46: ...44 FORM NO 56043089 AquaRide BRX 700 RECOVERY SYSTEM FIGURE 3 ...
Страница 49: ...RECOVERY SYSTEM FORM NO 56043089 AquaRide BRX 700 47 FIGURE 5 FIGURE 6 ...
Страница 55: ...ELECTRICAL SYSTEM FORM NO 56043089 AquaRide BRX 700 53 FIGURE 4 FIGURE 3 ...
Страница 72: ...70 FORM NO 56043089 AquaRide BRX 700 ELECTRICAL SYSTEM Drive Motor Breakdown ...
Страница 79: ......
Страница 82: ...www nilfisk advance com 2005 ...