64
30 - Solution System
EcoFlex Control Panel
For machines equipped with the option EcoFlex
system, the standard solution control panel is
replaced with the EcoFlex control panel
1 Remove the 4 screws that secure the control
panel to the solution tank, and lift the panel
away from the tank
2 Disconnect the electrical connector, and
remove the control panel
Specifications
Parameter
Range
Solution Solenoid
Coil Resistance
105 Ω
Detergent Pump Coil Resistance
37 Ω
A
B