STEP
1. Connect and test the
power supply. If it tests OK,
unplug the connector from
the power socket and pro-
ceed.
2. Connect the first Sensor/
Keypad cable to either one of
the Sensor inputs.
3. Test for shorts and interfer-
ence.
DESCRIPTION
A) Plug the supplied 12vDC power supply into an unswitched
120V AC outlet .
B) Plug the connector into the socket marked “Power” on the
IRP2+.
C) If the Power LED does not light, test the unswitched 120
VAC outlet with another appliance. If the outlet tests OK, you
have a defective power supply which must be replaced for you
to continue.
A) Strip 1/4” of insulation from the wire ends of the cable.
B) Attach the exposed wire ends to the appropriate connector.
Be careful to prevent a filament of wire from shorting out two
connectors. Red = +12v Bare = GND Black = DATA
A) Reconnect the power supply. If the Power LED lights and
the IR Test LED stays off, unplug the connector from the
power socket and proceed to Step 4. The following LED con-
ditions show a fault:
• If Power LED is Off there is a short b12v and GND
• If IR Test LED is On or Flickers there is a short between DATA
and GND Or Interference is present.
Before you proceed to Step 4 consult the Troubleshooting
Section beginning on page 12