background image

14

U

SI

N

G

T

H

E

R

EM

O

T

E

T

R

IG

G

ER

FE

A

T

U

R

E

USING THE REMOTE TRIGGER FEATURE

Trigger Activation

Your AC-6+ has (2) Trigger Inputs and (1) Bus Trigger Output which provides a wide array of possi-
bilities for automated turn-on and shut-off of the Triggered outlets. Each Trigger Input can be acti-
vated with 12V DC 200mA input via standard 3.5mm mini plug jacks found on the AC-6+. This
dual-trigger input configuration allows for two zone control of the system, while the single bus out-
put allows the AC-6+ to be "daisy chained" to other iPOWER

products or any other 

protected, triggerable device. In addition, the Trigger Output can be utilized to generate a “power
status” signal for use with compatible Niles infrared or audio/video distribution products.

Using The Trigger Inputs

NOTE:The Triggered outlets can only be triggered by the Trigger Inputs if the Power button is initiated.

Your AC-6+ has (2) Trigger Inputs which can be used for remote turn ON and turn OFF of the
Triggered outlets. The Trigger can be activated with any 12V DC trigger voltage. Many control ampli-
fiers, preamps/receivers and system integration centers have a voltage output which can be used to
activate the AC-6+’s Trigger feature. If your system includes a control device with provisions for
remote triggering, simply connect the voltage output from the control device to the Trigger Input on
your AC-6+. If the control device has a switched outlet, plug the 12V DC 200mA Remote Trigger
Power Supply (included) into the control’s device switched outlet and the 3.5mm mini plug into one
of the AC-6+’s Trigger Inputs (see illustration, next page). Now, every time the control device’s

IMPORTANT NOTE

All components in a system must be connected to an iPOWER

Power Management System in order for

the system to be protected from electrical disturbances and to realize maximum noise filtration benefits.
This includes AC power cables, coaxial connections, and telephone cables used with pay-per-view 
systems. Failure to do this will degrade system performance and leave it vulnerable to electrical damage.

Содержание iPower AC-6

Страница 1: ...Intelligent Power Management Systems I N S T A L L A T I O N O P E R A T I O N G U I D E B L E N D I N G H I G H F I D E L I T Y A N D A R C H I T E C T U R E AC 6 AC 6 6 OUTLET POWER MANAGEMENT SYSTE...

Страница 2: ...imited Lifetime Warranty and Connected Equipment Guarantee All rooftop devices connected to your iPOWER products should be grounded according to the National Electrical Code NEC Do not place any rooft...

Страница 3: ...he cord meets the plug and where the cord enters the device WARNING Object And Liquid Entry Care should be taken that no objects or liquids fall onto or into the device Do not use alcohol on the devic...

Страница 4: ...signers intended while being fully protected from electrical noise and poten tially damaging spikes and surges In addition to power protection and performance enhancement the iPOWER AC 6 offers trigge...

Страница 5: ...ECHNOLOGIES 4 UNIT DETAILS 7 INSTALLATION OVERVIEW 8 PACKAGE CONTENTS 9 PLANNING YOUR SYSTEM 10 PLANNING YOUR AC CONNECTIONS 12 MAKING CONNECTIONS 13 USING THE REMOTE TRIGGER FEATURE 14 TROUBLESHOOTIN...

Страница 6: ...erms of delivering instantaneous response time Its clamping levels are among the lowest in the industry providing unrivaled electrical protection for its connected equipment Its iQ Optimal Q Impulse N...

Страница 7: ...nology have a consistent clamping level of less than 300V In addition all iPOWER products clamp at a mere 40V over peak standard line voltage ANSI IEEE C62 45 6000V 100 kHz Ring Wave Test adding a lev...

Страница 8: ...larly useful in older homes where electrical systems may have been installed at different times during the life of the home When illuminated the Ground OK LED on the AC 6 indicates that the house wiri...

Страница 9: ...here is 12 volts present at the 12 Volt Trigger Inputs UL 1449 Second Edition Listing The UL 1449 Second Edition procedure is considered to be the most rigorous and demanding series of tests for surge...

Страница 10: ...d that Triggered outlets are in standby mode Ground OK LED indicates that the wall outlet wiring is properly grounded Line OK LED indicates that the wall outlet is free of any problems such as a polar...

Страница 11: ...e it will be used being sure to follow both the safety pre cautions listed in the front of this manual and the placement recommendations on page 11 DO NOT plug the unit in yet Plug each of the compone...

Страница 12: ...1 AC 6 1 12V 200mA remote trigger power supply PACKAGE CONTENTS PACKAGE CONTENTS 1 Installation Operation Guide 9...

Страница 13: ...n iPOWER Power Management System in order for the system to be protected from electrical disturbances and to realize maximum noise filtration benefits This includes AC power cables coaxial connections...

Страница 14: ...ounting screw slots are provided on all AC Series iPOWER products for such purposes On the back of each unit you will find a series of L shaped slots designed to accommodate mounting screws The L shap...

Страница 15: ...described above Triggered Outlets The Triggered outlets enable the connected devices to power on and off automatically When the Power Button is initiated it places theTriggered outlets in stand by mo...

Страница 16: ...tlets IMPORTANT NOTE All components in a system must be connected to an iPOWER Power Management System in order for the system to be protected from electrical disturbances and to realize maximum noise...

Страница 17: ...ote turn ON and turn OFF of the Triggered outlets The Trigger can be activated with any 12V DC trigger voltage Many control ampli fiers preamps receivers and system integration centers have a voltage...

Страница 18: ...er allowing for multi zone operation 15 USING THE REMOTE TRIGGER FEATURE IMPORTANT NOTE IMPORTANT The control device must be plugged into the AC 6 to ensure proper protection The illustration offers o...

Страница 19: ...rough the AC 6 to another device Additional Remote Trigger Power Supplies If you require additional Remote Trigger Power Supplies they can be obtained from your autho rized Niles dealer Stock FG00665...

Страница 20: ...voltage below 12V Check the trigger source to be sure that the signal is 12V DC 200mA Check that the Power Button is initiated The Triggered outlets will not function if the Power button is not in the...

Страница 21: ...n supply Check with your Niles dealer or installer to see what other iPOWER products can be used in addition to the AC 6 to provide sufficient power for your system Many components will create thumps...

Страница 22: ...ts Energy dissipation 1550 Joules Line voltage 120VAC 15A 50 60 Hz Peak impulse current 100 000 Amps Protection Modes Line to Neutral Line to Ground Neutral to Ground EMI RFI noise reduction Up to 60d...

Страница 23: ...rive to improve our products Niles reserves the right to change product specifications without notice The technical and other information contained herein is not intended to set forth all technical an...