Operating Status Menu 

The system's current operating status is displayed as the initial screen in the main menus. 

OFF

 

 

 

The system is switched off. All functions are inactive, except:

 

Alarm from ground pipe environmental pressure switch 

Circulation pump periodic test run and frost protection 

START

 

 

 

Start heat pump. Circulation pumps start. Switch after a short time to operational

 

READY

 

 

 

The system is switched on but there is no current heat demand 

HEATING

 

 

 

Room heating. Central heating temperature in the house at the desired value

 

WATER

 

 

 

Domestic hot water production 

MANUAL

 

 

 

The user has activated manual operation via the service menu 

ALARM

 

 

 

Alarm device triggered. The system continues to operate but with reduced function

 

STOP

 

 

 

The system was stopped due to a critical malfunction 

 

Operating Mode Menus 

In the OPERATION menu, the following operating modes can be selected: 

OFF

 

 

 

No heating functions are active 

SUMMER

 

 

 

Normal condition is domestic water. Central heating is not active 

WINTER

 

 

 

Normal condition is central heating, which switches to domestic water as needed 

AUTO

 

 

 

The system selects operating mode based on average outside temperature, 
set summer temperature and a 3°C neutral zone 
- Winter: After 24 hours under summer temperature minus neutral zone

 

- Summer: After 24 hours above summer temperature 
When  user  function  HEATING  has  been  choice  in  "SELECT"  in  the  "SERVICE", 
summer/winter mode is chosen by an external signal on digital input DI4

 

 

Main Menus 

Parameters in 

blue

 text below can be adjusted by authorized service personnel / user. The product 

is delivered with factory settings as indicated. 
Shaded cells must often change 
 

STATUS * 
  HEATING

 

 

 

 

Readout of current operation status text 
* Symbol indicates that a user function is active on the digital input 
This is the main screen 

OPERATION

 

WINTER

 

 

 

  The unit's main switch and selection of overriding operating mode 

In operating mode AUTO the choice can be by user function HEATING on digi-
tal input. [OFF, SUMMER, WINTER, AUTO] 

T USER 
EXT 

15

°C

 

 

 

 

Alternative setting selected via user function digital input 
(shown only if a user function with setting is selected (COOL, DELAY) 

READOUT 
       

 

 

 

 

Sub-menu for display of current sensor and control data 

 

T WATER 
    45°C

 

 

 

Domestic water tank temperature   

 

T HEAT* 
CURRENT 
33°C

 

 

 

Central heating temperature 

 

T HEAT* 
SET 32°C

 

 

 

Current  setting  for  central  heating  temperature.  Recommended  flow  central 
heating  temperature  is  30  °  C  to  45  °  C.  Fixed  value  or  variable  value  using 
outdoor compensation.

 

 

T OUT 
    12°C

 

 

 

Outside temperature 

 

EVAP. T

 

    -2°C

 

 

 

Evaporator  temperature,  Indicates  the  temperature  of  the  cooled  brine  in  the 
evaporator   

 

CP CAP 
     60 % 

 

 

Current compressor capacity (%) 
(shown only if compressor speed control is selected) 

CURVE 
+/-  

0

°C

 

 

 

 

Raises or lowers the calculated curve setting a fixed value (°C) [-9..9]  (shown 
only if curve control is selected)  - See the menu CENTRAL HEAT 

 
* Version 1.09 displayed T HEAT as T RETUR 

 

Содержание LMC 223

Страница 1: ...JVP 3 Version 6 00 14 09 2012 Software 1 11 This guidance applies to JVP 3 740023 SW 1 09 Installation and User Guide LMC 223 by Nilan...

Страница 2: ...us 15 Main Menus 15 Function Description 20 Heat pump compressor 20 Frequency controlled compressor variable capacity 20 Ground pipe and brine 20 Condenser and heating circulation pump 20 Permitted ar...

Страница 3: ...re 3 LMC 223 Control Unit 13 Figure 4 Curve Selection for external temperature compensation 22 Figure 5 Structural ground source pump system diagram 27 Figure 6 Example of layout of ground pipes in a...

Страница 4: ...dealer Find your local dealer here www nilan dk forhandlere Control of the system is via a NILAN LMC 223 control unit which offers a wide range of functions for example menu driven control summer wint...

Страница 5: ...eating and brine ground source loop Safety valves for central heating and brine ground source loop Low and high pressure cut off switches for compressor Pressure guard brine loop ground pipe mandatory...

Страница 6: ...a low temperature in the brine to a higher temperature in the central heating system Circula tion pumps 8 maintain flow in both the ground pipe loop 3 and the central heating floor heating loop 10 Th...

Страница 7: ...ntral heating loop and the ground source loop have been ventilated The central heating circuit has an excess flow valve or other circulation which ensures the flow see Figure 5 no 28 Check list for br...

Страница 8: ...ol The heat pump is equipped with a low pressure switch which ensures that the brine never be comes so cold that it freezes solid and thus the ground source heat pump s heat exchanger is protected aga...

Страница 9: ...ved Page 9 of 33 item 18 and 19 By means of a combined filling and venting tank the brine loop is filled through the filler tap until the loop is compeletely full Figure 5 Structural ground source pum...

Страница 10: ...All rights reserved Page 10 of 33 item 13 Duration minimum 1 hour The shutter tap at the cirkulation pump in the brine loop Figure 5 Structural ground source pump system diagram...

Страница 11: ...diately if you suspect leakage Water pressure in the central heating loop The water pressure in the central heating loop must initially be inspected as often as several times a day Top up the system w...

Страница 12: ...cient to check the filter twice a year Cleaning the dirt filters Switch off the heat pump at the main switch Close the shut off valves on each side of the filter Pull out filter and rinse until clean...

Страница 13: ...light in the display is illuminated when the unit is being operated The light switches off after 30 seconds if the unit is not activated by the user The control unit will revert to the start screen s...

Страница 14: ...e until the service menu is displayed Press the knob to activate the service menu Turn the knob until the LANGUAGE menu is shown in the display Press the knob The text in the display flashes Turn the...

Страница 15: ...user function HEATING has been choice in SELECT in the SERVICE summer winter mode is chosen by an external signal on digital input DI4 Main Menus Parameters in blue text below can be adjusted by auth...

Страница 16: ...ST DIFF 40 Compressor start difference shown only when RPM compressor level selected U MIN 25 Minimum voltage to frequency converter shown only when RPM compressor level selected U MAX 100 Maximum vo...

Страница 17: ...l heating temperature is 30 C to 45 C By TEMP CTR AMB COMP will restrict the central heating temperature downwards and must therefore be adjusted the curve T HEAT MAX 45 C The maximum permitted setpoi...

Страница 18: ...al heat pump system DEFROST CAP 80 Not a function of Geothermal heat pump system NUM HG 0 Not a function of Geothermal heat pump system NUM AIR 0 Not a function of Geothermal heat pump system LAST DE...

Страница 19: ...ser function in digital input DI4 NONE DEFROST COOL DELAY HEATING MANUAL Manual activation of relay outlets ACTIVATE NO Activation of manual operation NO YES COMPRESS OFF Start compressor OFF ON AUX O...

Страница 20: ...nder 10 If the compressor continues to start stop at short intervals it may be necessary to set a wider neu tral zone in the CENTRAL HEAT NEUTRAL ZONE Menu Ground pipe and brine The brine pump always...

Страница 21: ...zone The sys tem thus ensures that the heat pump supplies the greatest share of energy At the same time the user even during extraordinary demand is ensured a well defined comfort The heat pump is de...

Страница 22: ...is of these temperatures the central heating temperature is determined by interpolating between the points for a given outside temperature see Figure 4 For outside temperatures under 20 C and over 20...

Страница 23: ...nsors or system components can of course render this protection inef fective When the outside temperature falls below 2 C the central heating circulation pump will start With that any spaces under the...

Страница 24: ...ting too slowly Possible causes 1 Dirt filter in the central heating system is clogged 2 There is air in the central heating system ventilate the system 3 There is insufficient water in the central he...

Страница 25: ...und pipes are leaking Check the following 1 Are all cocks open that should be open 2 Is there enough brine in the system Top up if necessary Check 1 2 and correct the fault Acknowledge the alarm by pr...

Страница 26: ...essor auxiliary heating takes over heat ing Low pressure alarm The heat pump will start auto matically two minutes after the alarm has disappeared 33 HIGH PRS W Stop compressor auxiliary heating takes...

Страница 27: ...All rights reserved Page 27 of 33 Installation Figure 5 Structural ground source pump system diagram...

Страница 28: ...ith software version 1 10 of LMC223 this works as an external summer winter shift In the controller menu SERVICE SELECT USER FUNK can be select HEATING When HEATING is chosen you make and extreme chan...

Страница 29: ...All rights reserved Page 29 of 33 Figure 6 Example of layout of ground pipes in a collector Figure 7 Example of layout of ground pipes with collection inside footing...

Страница 30: ...lling them with brine Calculate pumping time for filling the system at an established pumping rate It will not take less than the calculated pumping time to fill the system with brine Prevent air from...

Страница 31: ...pe N A Brine concentration N A The brine concentrationen freezing temperature registered 20 C til 18 C N A C The brine is properly mixed prior to filling of the circuit The brine cicuit is purge of ai...

Страница 32: ...s mounted correctly and has correct opening pressure The is a bypass which ensures a sufficient flow through the condenser eliminates HP cut out The circulation pump must be dimensioned for the specif...

Страница 33: ...case a remote running signal from the heat sys tem is used connection must be made and heat pump controller configured for this Supplementing electrical heating element is acti vated if required after...

Отзывы: