PROCEDURE FOR CHANGING THE HEPA FILTER
(1) The precautionary steps described in this manual should be used when changing the
HEPA filter.
(2) NOTE: You must follow Local and 1 or Federal guide lines when working with
contaminated filters.
(3) Remove the eight (8) bolts holding the HEPA filter to the filter mounting plate,
using a Phillips screw driver and a 11/32" wrench.
(4) Carefully remove the HEPA filter from the filter mounting plate, being careful not
to create any airborne dust.
(5) This filter cannot be cleaned, and should be disposed of in an appropriate manner.
(6) Re-install the new HEPA filter using #8 screws, nuts, lock washers, and flat
washers.
(7) Replace the impaction filter, on the HEPA filter.
(8) Re-connect the filter protector cage.