Operational Summary
Riflescope
1. Diopter adjustment
盧
Look through the eyepiece with your eye positioned about 4 inches away from the eyepiece lens (Fig. 9), and you will see the Nikoplex reti-
cle (Fig. 10), or the BDC reticle (Fig. 11).
Be sure your eye is positioned within progper alinment and proper eye relief otherwise the view will "black out".
盪
Point the objective end of the scope at the sky (Do not point at the sun) or at a plain unpatterned wall.
Turn the eyepiece adjustment counter-clockwise and then turn it clockwise until the reticle appears sharp.
2. Magnification
蘆
The Laser IRT 4-12X42 has a variable magnification from 4 to 12X.
To change powers. just rotate the power selector ring until the desired magnification appears adjacent to the power index dot (Fig. 2).
3. Adjustment of the riflescope
Sighting through the riflescope, align the rifle with your aiming point on the target and shoot a trial round. If the bullet does not hit the
aiming point, adjust the elevation and windage after removing the Adjustment cap, as follows:
4-12X42
蘆
For the Laser IRT adjustment is made by turning the grip by hand. If the bullet hits under the aiming point, turn the grip in the direction of
the arrow marked "U". If the bullet hits to the left of the aiming point, turn the grip in the direction of the arrow marked "R" (Fig. 12).
Note:
蘆
The windage and elevation scales of the Laser IRT 4-12X42 is calibrated in divisions of 1/4 minute of angle with a click at intervals of 1/4
minute of angle (half division).
蘆
When adjusting the reticle to the point of aim, remember that one minute of angle equals approximately one inch (2.54 cm) at 100 yards
(91.44 m). Therefore, if the impact point is two inches (5.08 cm) low and one inch (2.54 cm) right at 100 yards (91.44 m) Parallax Setting,
you should adjust two minutes of angle up one minute of angle left.
Laser Range Finder
Caution - use of controls or adjustments or performance of procedures other than those specified herein may result in haz-
ardous radiation exposure
1. Install a battery in the battery chamber. (See "Changing Batteries")
2. Diopter adjustment
Refer to Riflescope Diopter ajustment.
Depress POWER or REMOTE
control button over 2 seconds
until the display changes
START
−
C
−
Depress Remote
control button
Depress
Power button
Align the reticle cross
and Target
Measurement
"Distance" or "
−−−
"
(Success or Failure)
Over
12 seconds
Over
8 seconds
Measurement
"Distance" or "
−−−
"
(Success or Failure)
Stand-by mode *
Power OFF **
Over
2 hours
Over
2 hours
Stand-by mode *
Power OFF **
Over
8 seconds
or
Repeat
action
another
target
same
target
No
No
No
Change to Measurement mode
START
Depress Remote
control button
Depress
Power button
Align the reticle cross
and Target
or
Depress Remote
control button
Depress
Power button
or
−
O
−
(Display on seven segment)
(Operation of Unit)
(Action of Unit)
Normal (continuous) measurement mode
ONE SHOT measurement mode
3. Measuring
Eyepiece Adjustment
Eye Relief
Fig. 9
Fig. 12
4. Selecting measurement mode
蘆
Continuous measurement
The instrument continuously measures distance for 12 seconds.
Depress POWER or REMOTE
control button over 2 seconds
until the display changes
Normal
(continuous)
measurement
mode
One shot
measurement
mode
Change to Measurement mode
Specifications
★
When maximum magnification (12x) is selected.
* (at minimum magnification) - (at maximum magnification)
** moa = minute of angle
***The battery chamber is water resistant, not waterproof. Water may enter the device if the laser IRT is submerged in water. If water enters the
battery chamber, wipe out any moisture and allow time for the chamber to dry.
●
Waterproof models:
The Laser IRT is waterproof, and will suffer no damage to the optical system if submerged or dropped in water to a maximum depth of 2 meters
for up to 5 minutes.
The Laser IRT offers following advantages:
蘆
Can be used in conditions of high humidity, dust and rain without risk of damage.
蘆
Nitrogen-filled design makes it resistant to condensation and mold.
Observe the following when using the Laser IRT:
蘆
As the unit does not have a perfectly sealed structure, it should not be operated nor held in running water.
蘆
Any moisture should be wiped off before adjusting movable parts (Power selector Ring, eyepiece, etc.) of the Laser IRT to prevent damage and
for safety reasons.
To keep your Laser IRT in excellent condition, Nikon Vision recommends regular servicing by an authorized dealer.
Troubleshooting/Repair
If your Nikon Laser IRT should require repair, please contact your local dealer for details regarding where to send it. Before doing so, you are
advised to consult the Troubleshooting Table below.
Check Points
蘆
Depress POWER button.
蘆
Check and replace battery if necessary.
蘆
Be sure that nothing, such as your hand or finger, is blocking the laser emission aperture
and laser detector.
蘆
Be sure that the laser emission aperture and laser detector are clean. Clean them if neces-
sary.
蘆
Be sure that the target shape and condition is appropriate to reflect the laser beam.
蘆
Replace battery.
蘆
Be sure to hold the unit steady while depressing the POWER button.
蘆
Be sure the target is within measuring range (33-766 yards)
蘆
Be sure that nothing, such as leaves or grass, is between the Laser IRT and the target.
蘆
Be sure that nothing, such as leaves or grass, is between the Laser IRT and the target.
蘆
Replace battery.
蘆
Be sure that the target shape and condition is appropriate to reflect the laser beam.
蘆
Be sure to hold the unit steady while measuring the distant.
蘆
Be sure that nothing, such as leaves or grass, is between the Laser IRT and the target.
蘆
Replace battery.
蘆
Be sure that the target shape and condition is appropriate to reflect the laser beam.
蘆
Be sure that nothing, such as leaves or grass, is between the Laser IRT and the target.
Symptom
Unit does not turn on - LED fails to illumi-
nate
Target range cannot be obtained
[
−−−
] ("Cannot measure") appears
Closer target cannot be measured
Target beyond a certain distance cannot
be measured
Measurement result is unstable
Incorrect result is displayed
4-12x42
4x-12x
42
1.65
3.5
★
0.14
★
74-75
2.9-3.0
7.6-2.5
25.0-8.2
52
2.05
330
13
700
24.7
1/4: 1 click
50
91.44
100
39
1.78
FDA Class I
905nm
26ns
0.036 degree
33-766 yards
1 yard step
Scope: Waterproof (maximum depth of 2 meters for up to 5 minutes),
Battery chamber: Water resistant ***
−
10
°
to
+
50
°
Attachable to a gun with Velcro
Scope: 3 volts DC, CR-2 lithium battery x1
Remote control unit: 3 volts DC, CR2025 lithium battery x1
21 CRF PART 1040.10: 1985
FCC Part 15/Sub Part B Class B
MODEL
SCOPE
Actual magnification
Objective diameter
(mm)
(in)
Exit pupil
(mm)
(in)
Eye relief
(mm)
*
(in)
Field of view at 100 yds.
(m)
*
(ft)
Objective outside diameter
(mm)
(in)
Length
(mm)
(in)
Weight
(g)
(oz)
Adjustment graduation
**
(moa)
Maxinum internal adjustment
**
(Elevation & Windage)
(moa)
Parallax setting
(m)
(at factory)
(yards)
Outside Diameter of
(mm)
Eyepiece
(in)
Laser
Class
Wavelength
Pulse duration
Output
Beam Divergence
Others
Measuring range
Distance display
Structure
Operating temperature
Remote control unit
Power source
Safety & EMC
If problems persist after consulting the Troubleshooting Table, please contact your local dealer to check/repair the Laser IRT. Never let anyone
other than the official representative of the product manufacturer check or repair the Laser IRT. Failure to follow this instruction could result in
injury, or damage to the product.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera-
tion.
Do not use the Laser IRT for purposes beyond the limits of its stated accuracy.
Stand-by mode *
Unit accepts operation with Remote control unit.
Power OFF **
Unit does not accept operation with Remote control unit.
At Power OFF mode, before using the Remote control unit Power switch must be depressed.
Nikoplex Reticle
Fig. 10
BDC Reticle
Fig. 11
ITEM SUPPLIED
Body...................................................1pc.
Eyepiece cap
Objective cap
..............................1pair
Battery (CR2 & CR2025)............1pc. each
Hood..............................................Option