JAA79201-R.3669.A
- A7・ AF-S 18-55/3.5-5.6G -
Fixed tube unit
Fig.1
CH1
CH2
Fig.2
CH1
CH2
<
Ref.
>
● As shown in Fig. 1, if the amplitude of only either CH1 or CH2 is small, one of the 2 screws (#218) may be
loosened, so check for it. If this is not the case, the MR head may malfunction, so replace the MR holder
unit and make a readjustment.
●
As shown in Fig. 2, if the amplitude partially drops between the infinity and the close-distance, the
magnetic data of the tape may be damaged. So replace the main fixed tube unit and make a readjustment.
Replacing only the magnetic surface is impossible.
⑦
Turn off the rated voltage power-supply.