4. Electrical Specifications 

 
 
 

11 

Safety standards 

This product meets EU Low Voltage Directive requirements. 
This product meets EU EMC Directive requirements.(EN61326) 
This is UL-listed product. (UL61010-1) 
This product meets FCC Part 15B Class A requirements. 

This equipment has been tested and found to comply with the limits for 
a Class A digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial 
environment. 
This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause 
harmful interference      in which case the user will be required to correct 
the interference at his own expense. 

Temperature 

0°C to 40°C 

Humidity 

85% RH max. (no condensation) 

Altitude 2000 

max. 

Operating conditions 

Degree of pollution 

Degree2 

Temperature 

-20°C to 60°C 

Storage conditions 

Humidity 

90% RH max. (no condensation) 

 

 

 

 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание DXM1200C

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ...DIGITAL CAMERA DXM1200C for Microscope Hardware Instruction Manual M367 E 05 9 XF 1 2 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 4: ...formation on how to install the ACT 1 DXM1200C application program on your PC and use it see the software instruction manual No part of this manual may be reproduced without Nikon s permission The content of this manual is subject to change without notice Nikon has carefully prepared this manual However we make no expressed or implied warranty of any kind and assume no responsibility for such erro...

Страница 5: ...ot disassemble the DXM1200C To prevent malfunction and electric shock never disassemble any part of the DXM1200C unless you are explicitly directed to do so in this manual Contact your distributor should you determine that the DXM1200C does not function properly 3 Check the power source The DXM1200C is powered by your PC Make sure that your PC meets relevant safety standards Read your PC instructi...

Страница 6: ... or malfunction 2 Shutting down the PC Before assembling the DXM1200C system connecting the cable or disconnecting it be sure to shut down your PC to prevent malfunction 3 Connectors To prevent malfunction and accident connect only specified equipment to the connectors provided on the camera and the interface board 4 Precautions on assembly installation and storage Watch your fingers or hands They...

Страница 7: ...sed in This Manual 2 Warning 2 Caution 3 Contents 4 Chapter 1 System Configuration 5 Chapter 2 Assembling 7 Chapter 3 Maintenance 9 Chapter 4 Electrical Specifications 10 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 8: ...implified Chinese ver Windows 2000 professional Service Pack 4 or later Windows XP Japanese English Simplified Chinese ver Windows XP Professional Service Pack 2 or later Note When a SCSI controller board is installed into the PC the DXM1200C may not work correctly In that case remove the SCSI controller board from the PC Display monitor Minimum resolution and colors are 1024 x 768 pixels and 16 7...

Страница 9: ...unt adapter optional Interface cable connector Interface board Vertical tube of microscope PC AUX terminal Top view Rear view Bottom view Interface cable connector Tripod screw C mount screw Ferrite core Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 10: ...on the PC before mounting the interface board 1 Read your PC instruction manual before mounting the interface board 2 Remove and save the screws from the PCI slot You will be using these screws later to secure the interface board 3 Remove the cover from the PCI slot Keep the cover for later use 4 Carefully insert the interface board into the PCI slot Avoid touching the motherboard and other compon...

Страница 11: ... ON the power to your PC When you start Windows for the first time after the interface board has been attached Windows has found new hardware and is locating the software for it appears At this time install the interface board driver See The DIGITAL CAMERA DXM1200C for Microscope Software Instruction Manual for more information on installing the driver Supplementary information The camera is power...

Страница 12: ... alcohol ether or paint thinner to clean painted plastic or printed areas These solvents will damage or discolor finished and painted surfaces and erase panel markings Nikon recommends silicone based cleaners for cleaning Storage Shut down your PC if you do not intend to use the DXM1200C for a while If you do not plan to use the DXM1200C for an extended period remove the interface cable from the c...

Страница 13: ...position can be arbitrarily set Operation mode Continuous mode or one push mode Automatic exposure Exposure correction 8 stages Image record format BMP JPG TIFF non compression JPEG2000 loss less compression Orientation of image Right and left reversing Upper and lower reversing CW CCW 90 degree rotation Frame rate for motion pictures 15 frames or less second 686 512 pixels mode PC Interface PCI b...

Страница 14: ...ed in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expe...

Страница 15: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Отзывы: