A22
・
-
VBA12001-R.3668.A
・
Measure 4 parts from the bayonet face to the CCD-PCB
attaching face.
Standard:48.25±0.015mm/ Parallelism: within 0.015mm
・
In case it is out of standard, make an adjustment
by loosening screws that attach the front and rear bodies,
or
by putting the washer(s) on the contact surface be-
tween the front body and rear body.
Measuring points
*
"0" positioning of the dial gauge
Inspection and Adjustment of Body back
0" position of D50
①
Put the tool (J18001-1) on the surface plate, and set the dial gauge to "0".
②
Turn the index ring to shift the position by "0.42 mm" from "0" that was set in
①
.
(This position is "0" of D50.)
③
Measure the body back based on "0" reference position of the index ring.
Surface plate
Note: For some bodies, washer(s) are already put on the attaching face of the CCD-bracket.
There are 2 cases as follows.
1. Purpose
:
To adjust the height of the camera body
There are indications(color mark) on the camera body side of the CCD-PCB attaching face.
{Blue =0.02mm (#87), Red
=
0.1mm (#88), Green
=
0.06mm (#89)}
*
By adding the measured value to the thickness of washers, check if it is within the standard
(48.25±0.015mm).
2. Purpose
:
To adjust the height of the CCD bracket
There are indications(color mark) of the CCD-bracket attaching face
{
Red 2 lines
=
0.02mm (#87), Red 1 line
=
0.1mm (#88)}
*
When the CCD PCB is replaced, remove the washers.