VBA10201-R.3577.A
-
E8
・
-
②
Display
②
-1: External LCD: F80 drive voltage 5.7V is changed to 5.4V. The display pattern is changed.
②
-2: LCD in F: Only the display pattern is changed. The drive voltage is the same as F80/N80.
②
-3: SILCD: The same product as F80/N80 is used. The drive voltage 5.7V is changed to 5.4V.
③
Control units
③
-1: Change of the built-in SB circuit PCB
To prevent collision against the lithium ion battery protection circuit, the following functions
and circuit are added: limit of the charge current, detection of overcharging and thermal protec-
tion circuit
③
-2: Inspection communication
One method is to contact by removing the bottom cover, and the other is communication via
RISC (USB).
③
-3: System reset switch
The system reset switch is set on DC-IN.
Reason of setting: The sub MCU is equipped with the backup battery and so, if an accident has
occurred, the instrument cannot be reset by turning on/off the main power
supply.