- A46
・
-
• Open aperture sensitivity compensation
(1) Set the luminance of the brightness box (shutter tester) to “LV9”.
(2) Set a lens of 50mmF1.4D (a ready-made product) onto the camera.
(3) Set the focus ring of the lens to “infinity”.
(4) Select “Open aperture sensitivity compensation” in “Contents” on the menu display.
(5) Supply the power to the camera through the AC cable.
(6) Connect the USB cable to the camera.
(7) Set the camera onto the luminance surface of the brightness box with nearest distance.
(8) Press the START button. Perform the procedure according to the instructions on the screen.
(9) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG, “NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(10) Remove the USB cable from the camera and then remove the AC cable.
• Built-in speed light adjustment
(1) Set a lens of 50mmF1.4D (a ready-made product) onto the camera.
(2) Set the focus ring of the lens to “1.4m”.
(3) Set the camera at a 1.4m position from the standard reflect paper. Look into the finder to make sure that the
standard reflect paper is seen on the whole screen.
(4) Supply the power to the camera through the AC cable.
(5) Connect the USB cable to the camera.
(6) Select “Built-in speed light adjustment” in “Contents” on the menu display.
(7) Press the START button. Perform the adjustment according to the instructions on the screen.
(8) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG, “NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(9) Remove the USB cable from the camera and then remove the AC cable.
• Battery check level adjustment
(1) As shown below (Fig. 2), connect the constant-voltage power supply, voltmeter and ammeter to the battery
tool (without resistor).
(2) Set the voltage of the constant-voltage power supply to 7.2 [V].
(3) Set the battery tool (without resistor) onto the camera and start the camera.
(4) Connect the USB cable.
(5) Select “Battery check level adjustment” in “Contents” on the menu display.
(6) Press the START button. Perform the procedure according to the instructions on the screen.
(7) The adjustment result is displayed at the result display position. If “OK” is displayed, the adjustment is
normally ended. If the adjustment is NG, “NG” is displayed and the contents of the error are displayed in
the column of “COMMENT”.
(8) Remove the USB cable from the camera and then remove the AC cable.
Содержание D100 VBA10201
Страница 19: ...VBA10201 R 3577 A D13 Prism Box Unit 1 Removal of Prism Box Unit from Front Body 688x4 ...
Страница 21: ...VBA10201 R 3577 A D15 AF Sensor Unit TTL SPD Unit 170x3 602x3 B2163 B2004 625x2 200 ...
Страница 27: ...VBA10201 R 3577 A D21 Bottom Plate Unit 607x2 677x2 832x2 830 103 102 677 109 101 66 ...
Страница 67: ...VBA10201 R 3577 A A37 Bottom Cover 805 662x6 806 664 Open the I F cover Tighten the screws in order of to ...
Страница 81: ... ...
Страница 83: ... ...