JAA78071-R.3583.A
- L33 ・ AF-S 24-85/3.5-4.5G -
ADJUSTMENT FOR FREQUENCY AND CONTROL
●
In case of replacing the main PCB, SWM unit or MR encoder unit, be sure to make this adjustment.
①
The connection of the rated voltage power supply and measuring tools is the same as "ADJUSTMENT FOR
MR DUTY". Turn on the rated voltage power supply.
②
Make sure that the current and voltage of the rated voltage power supply are the set values.
③
Turn on the rated voltage power supply.
④
Select "2. ADJUSTMENT FOR FREQUENCY & CONTROL" in the menu items of the AF-S zoom lens (New)
inspection program. The lens starts driving for scanning automatically.
⑤
When the above display appears and the motor stops driving, select "1" to end the adjustment.
If the motor does not stop driving, select "2" to make the adjustment again.
If the adjustment is done again but the motor does not stop driving, adjust the MR duty again and then
perform "ADJUSTMENT OF DRIVING FREQUENCY AND MOTOR CONTROL" again.
If the adjustment is not successful yet, the SWM unit or cam ring unit may be defective.
TYPE OF LENS: AF-S NIKKOR 24-85mm/3.5-4.5G
CPU VERSION:4.00.04
ADJUSTMENT FOR DRIVING FREQUENCY & MOTOR CONTOROL.
ADJUSTMENT IS COMPLETED.
DOES THE MOTOR STOP DRIVING ? Yes =1 No =2
SELECT A NUMBER
PUSH ESC KEY TO RETURN TO MENU
Содержание AF-S Zoom-Nikkor ED 24-85mm f/3.5-4.5G IF
Страница 8: ...JAA78071 R 3583 A L6 AF S 24 85 3 5 4 5G SWM UNIT 96 3 B31 96 3 SWM unit ...
Страница 12: ...JAA78071 R 3583 A L10 AF S 24 85 3 5 4 5G ZOOM KEY 59 59 62 60 B7 3 1st LENS GROUP SLIDING RING 51 81 3 51 ...
Страница 13: ...JAA78071 R 3583 A L11 AF S 24 85 3 5 4 5G CAM RING 50 50 ...
Страница 24: ...JAA78071 R 3583 A L22 AF S 24 85 3 5 4 5G 96 3 3rd LENS GROUP 3rd lens group ...
Страница 46: ...JAA78071 R 3583 A F1 AF S 24 85 3 5 4 5G 外観図 Sketch drawings ...
Страница 47: ...JAA78071 R 3583 A F2 AF S 24 85 3 5 4 5G 組立図 Structure of the Lens ...
Страница 48: ...JAA78071 R 3583 A F3 AF S 24 85 3 5 4 5G ...