XXX-78400 SENSOR

3. Programming as light sensor

3.a. You wish an action if the value of the ambient light drops below the set light sensitivity value (e.g. a lamp 
must be switched on when it gets dark).

PIR

Nikobus module

1. Place the PIR in starting position (see  1).

2. Place the PIR in manual mode. The red LED lights 

up.

3. Place the Nikobus module in programming mode. 

Select the desired output and mode.

4. Turn the light sensitivity key completely to the right 

(sun). After a few seconds, the Nikobus telegram ‘light 
sensor on’ is sent.

5. Exit programming mode.

6. Turn the light sensitivity key completely to the left 

(moon) and wait for 5s. 

7. Place the PIR back into PIR mode (red LED goes 

out).

8. The PIR is back into starting position. Additional PIR 

sensors can now be programmed.

3.b. You wish an action if the value of the ambient light increases above the set light sensitivity value. 

Note:

 This option only functions in combination with single button modes. 

PIR

Nikobus module

1. Place the PIR in starting position (see  1).

2.Turn the light sensitivity key completely to the right 

(sun).

3. Place the PIR in manual mode. The red LED lights 

up.

4. Place the Nikobus module in programming mode. 

Select the desired output and mode.

5. Turn the light sensitivity key completely to the left 

(moon). After a few seconds, the Nikobus telegram 
‘light sensor off’ is sent.

6. Exit programming mode.

7. Place the PIR back into PIR mode (red LED goes 

out).

8. The PIR is back into starting position. Additional PIR 

sensors can now be programmed.

4. Remarks

- The PIR can only be programmed with single or double button modes. 
- Programming the PIR by briefly plugging in and out is strongly discouraged as the telegrams of the motion and lighting 

detection are then sent simultaneously. This leads to undesired switching of the programmed output(s).

- The use of the following Nikobus modes is recommended:
  With stand alone PIR sensors:
   

switching module: M1 (on/off)

   

dimming module: M1 (on/off)

  With PIR sensors switched in parallel:
   

switching module: M6 (delayed off)

   

dimming module : M7 (delayed off) 

- For programming automatic sensors (PIR, clock thermostate), the Nikobus software is recommended. 
-  If all the PIR motion detectors are programmed, you can set the desired light sensitivity and the turn-off delay 

by means of the potentiometers. 

Programming with Nikobus Windows

The PIR can only be programmed with single and double button modes!  

A combination of a PIR and a Nikobus actor behaves similar to a bus push button with 4 control keys.
The Nikobus telegrams that are sent by this combination, are defined as follows:

1. Programming as motion detector

Select channel 1 of the actor 430-0050X:
1A: PIR sensor on
1B: PIR sensor off.
Take into account the following behaviour of the PIR:
- When entering the detection field of the PIR, the telegram ‘PIR sensor on’ is sent.
- After the time set on the PIR is up, the telegram ‘PIR sensor off’ is sent. 

2. Programming as light sensor

Select channel 2 of the actor 430-0050X:
2A: light sensor on
2B: light sensor off.
Take into account the following behaviour of the PIR:
- When the value of the ambient light drops below the set light sensitivity, the telegram ‘light sensor on’ is sent. 
- When the value of the ambient light increases above the set light sensitivity, the telegram ‘light sensor off’ is 

sent. 

5. CAUTION DURING OPERATION

- Not to be used to isolate the system (by breaking the circuit)!
- Isolating the current circuit in order to replace defective lamps is only possible by switching off the isolator 

switch before it or by switching off the automatic circuit breaker.

6. LEGAL WARNINGS

- Read the complete manual before attempting installation and activating the system.
- The installation has to be carried out by a registered installer and in compliance with the statutory regulations.
- This user manual has to be handed over to the user. It has to be included in the electrical installation file and 

has to be passed on to any new owners. Additional copies are available on the Niko website or via the support 
service.

- During installation, the following has to be taken into account (not limited to list below):
  - The statutory laws, standards and regulations;
  - The state of the art technique at the moment of installation;
  - This user manual, which must be read within the scope of each specific installation, only states general 

regulations;

  - The rules of proper workmanship
- In case of questions, you can consult Niko’s support service or contact a registered control organisation.
  Support Belgium: 

Support UK:

  +32 3 760 14 82 

+44 1525877707

  website : http://www.niko.be 

http://www.nikouk.com

  e-mail: [email protected] 

[email protected]

In case of a defect, you can return your product to a registered Niko wholesaler, together with a clear description 
of your complaint (Conditions of use, stated defect…).

7. GUARANTEE PROVISIONS 

- Period of guarantee: 2 years from date of delivery. The delivery date is the invoice date of purchase of the 

product by the consumer. If there is no invoice, the date of production applies.

- The consumer is obliged to inform Niko in writing about the defect, within two months after stating the 

defect.

- In case of a failure to conform, the consumer has the right to a repair or replacement (decided by Niko) free 

of charge.

- Niko cannot be held liable for a defect or damage as a result of an incorrect installation, improper or careless 

use or wrong usage or transformation of the goods.

- The compulsory regulations of the national legislation concerning the sales of consumer goods and the protection 

of the consumers in the countries where Niko sells, directly or via sister or daughter companies, chain stores, 
distributors, agents or permanent sales representatives, take priority over the rules and regulations mentioned 
above.

8. CONNECTION DIAGRAM 

See manual of the corresponding actors.

FAULTFINDING TABLE

Fault 

Cause

Solution

Light does not work.

bulb faulty 

replace bulb

movement sensor mounted at wrong height

mount at the correct height (0,8m - 1,2m  - 2,2m)

heat emission does not register

Movement sensor does
not respond.

Response threshold in well-lit room is set for darkness.

set response threshold correctly

lens obstructed

clear lens

main switch or circuit breaker faulty

check and repair fault

Light is on continuously.

manual mode set

switch off manual mode

constant movement within the detection range

remove heat source form detection range
wait for turn-off delay time to elapse (max. 30min.)
set to shortest possible time
cover lens as a check

Manual mode cannot be set.

manual mode locked out

release lock

manual mode set

set automatic mode

Light switches on and off continuously.

distance to switched light insufficient

increase distance to light

Automatic and

 

undesired switching.

Switching on after the mains is switched off.

normal for the duration of the set turn-off time delay

sunlight falling on the lens or within the detection range
heat is projected into the detection range by reflection
heat/cold penetrating the detection range through open doors or windows

set response threshold for darkness

Содержание 78400 Series

Страница 1: ...dus gebeurt door kort 5s de knop bovenaan op het toestel in te drukken B Verhinderen van manuele modus Het is mogelijk om het omschakelen naar manuele modus te verhinderen Dit gebeurt via het aansluiten van spanning zelfde fase als voedingsspanning op de externe ingangsklem 1 E1 van de actor C Trappenhuisfunctie niet bij 10A actor 420 0010X Door via een drukknop N O of N G de spanning kort te onde...

Страница 2: ... is alleen mogelijk door de voorgeschakelde hoofdschakelaar of de automatische zekering uit te schakelen 6 WETTELIJKE WAARSCHUWINGEN De installatie dient te worden uitgevoerd door een erkend installateur en met inachtname van de geldende voorschriften Deze handleiding dient aan de gebruiker te worden overhandigd Zij moet bij het dossier van de elektrische installatie worden gevoegd en dient te wor...

Страница 3: ...tation C Mode de minuterie d escalier pas pour acteur 10A 420 0010X En interrompant furtivement par bouton poussoir N O ou N F la tension à la borne externe 1 de l acteur le détecteur enclenchera la charge pendant le temps de déclenchement retardé préréglé si du moins l intensité lumineuse est inférieure à ce moment à la valeur préréglée Cette fonction peut être combinée avec l interdiction d encl...

Страница 4: ...ée le télégramme détecteur de lumière arrêt est envoyé 5 AVERTISSEMENTS LORS DE L UTILISATION Ce détecteur de mouvement ne sert pas à mettre l installation hors tension La mise hors tension de l appareil pour effectuer un remplacement de lampes est uniquement possible par l ouverture de l interrupteur principal du circuit ou du disjoncteur 6 PRESCRIPTIONS LEGALES L installation doit être effectuée...

Страница 5: ...or 420 0010X Indem Sie über einen Öffner oder Schließer kurz die Spannung am Nebenstelleneingang desAktors unterbrechen wird der Bewegungsmelder den Verbraucher während der eingestellten Abschaltverzögerungszeit einschalten wenn der Lichtwert zu diesem Zeitpunkt die eingestellte Lichtempfindlichkeit unterschreitet Bei dieser Funktion kann auch der Handmodus über einen Schalter blockiert werden sie...

Страница 6: ... des Umgebungslichtes über den eingestellten Empfindlichkeitswert steigt wird das Telegramm Dämmerungsschalter AUS gesendet 5 HINWEIS ZUM GEBRAUCH Der Bewegungsmelder dient nicht um die Anlage auszuschalten durch Spannungsunterbrechung DasAusschalten der Netzspannung z B um defekte Lampen zu ersetzen ist nur möglich indem der vorgeschaltete Hauptschalter bzw der Sicherungsautomat ausgeschaltet wir...

Страница 7: ...ed by briefly pressing the button 5s at the top of the unit B Locking out manual mode It is possible to lock out switching to manual mode This is done by applying a voltage to the 1 external input terminal E1 of the actor same phase as power supply C Staircase function not with 10A actor 420 0010X By momentarily switching off the power at the 1 external input terminal of the actor via a NC or NO p...

Страница 8: ...d to isolate the system by breaking the circuit Isolating the current circuit in order to replace defective lamps is only possible by switching off the isolator switch before it or by switching off the automatic circuit breaker 6 LEGAL WARNINGS Read the complete manual before attempting installation and activating the system The installation has to be carried out by a registered installer and in c...

Отзывы: