STEREO ZOOM MICROSCOPE

Thank you for purchasing the Stereo Zoom Microscope.

Please read this instruction manual thoroughly before use to insure proper operation and long service.

glass

Rear

Fuse

AC Power Input

Upper Light

Upper Light

This is a precision instrument 

 Handle With Care. Use caution to avoid 

shock or excessive forces on instrument when in use or transport.

Use and store in location with low humidity and stable temperatures.

Avoid locations with dust, direct sunlight, excessive heat, or high vibration. 

Keep lens surface clean from dirt and fingerprints.

Clean the lens gently with lens cloth or soft cotton cloth.

Do not turn the left and right Zoom Controls in opposite directions; this 

will damage the instrument.

Before use, install the halogen bulb following the procedure below. 

Only use as directed. Improper use may cause accident or injury.

When not in use store with protective cover, in location that 

has low moisture in order to prevent internal mold growth.

Lighting unit not certified for use outside of Japan.

Remove the bulb cover from the Upper Light by rotating as shown. 

Use care not to drop or damage glass.

Insert the bulb into the 2-prong socket.

 ※

If not fully inserted, the bulb will not light but use care not to 

force or damage bulb when inserting.

Replace the bulb cover and rotate to tighten

PART IDENTIFICATION & SETUP

NOTES

SAMPLE PLACEMENT

EYE WIDTH ADJUSTMENT

EYE CUP USE

FOCUS & DIOPTER ADJUSTMENT

FUSE REPLACEMENT

SPECIFICATIONS

HALOGEN BULB INSTALLATION 

Place the sample in the center of the Stage Plate.

If required, use Stage Clips to hold sample in place.

Hold both sleeves in each hand and look through the Eyepieces. Adjust the 

Sleeves to align the left and right field of view seen through the Eyepieces.

For use without eyeglasses

Hold Eyepiece and rotate the Diopter 

Adjustment Ring to adjust diopter setting. Align the Eye cups to point 

toward user and look through the Eyepiece with eyes brought close.

For use with eyeglasses

Remove Eye cups to use.

In case of fuse failure, it can be 

replaced with a commercially 

available 250V 2A fuse.

Rotate the Zoom Control for highest magnification.

Look through the right eyepiece with the right eye and adjust the focus 

using the Focus Knob.

Rotate the Zoom Knob for lowest magnification.

Using the Right Diopter adjustment, adjust the focus if required.

Now rotate the Zoom Control back to highest magnification and check the focus.

Repeat steps 

②〜④

 to achieve the best focus accuracy.

Rotate the Zoom Control for highest magnification. Look through the left Eyepiece 

with the left eye, and adjust focus using the Left Diopter Adjustment Ring.

CAUTION

Halogen 

Bulb 

Installation

Halogen 

Bulb 

Installation

Bulb Installation

Rated Voltage

Magnification

Objective Lens
Eyepiece Lens
Working Distance
Eyepiece Angle
Focus Adjustment
Stand
Stage Plate
Eye Width Adj. Range
Diopter Adj. Range

Illumination

Base

Weight

ON

OFF

Socket 

Socket 

Fig.1

Fig.1

Fig.1

Tighten

Loosen

Fig.2

Fig.2

Bright

OFF

Insert

Upper Light
(Epi-Illuminator)

(Transmitted)

Light Power Control

Base

Lower Light

Power Sw.

Lower Light

Focus knob

350

470mm 

Range

60mm

AC100V

50/60Hz

6.5

45

×(

for 10

×

 eyepiece

13

90

×(

for 20

×

 eyepiece

0.65

4.5

×(

Zoom Ratio 1:7

WF10

×(

FOV = 20mm

WF20

×(

FOV = 10mm

95mm

45

°

Movable Body

Rack and Pinion Type

φ

95mm

×

2pcs 

Ground Glass 

black/white (plastic)

55

75mm

±

5diopter

Epi-illuminator: 6V

15W

Halogen bulb

Transmitted: 5W

ring light

L245

×

W190

×

H60mm

approx.5.7kg

Eye Cup

Eyepiece

Sleeve

Diopter Adj. Ring

Zoom Control

Stage Plate

Stage Clip

Head

245mm

190mm

Niigata seiki Co., Ltd.

5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522   Fax. : +81-256-33-5518

MAIL   [email protected]

URL    http://www.niigataseiki.co.jp

XTS2021

Model

No.

Instruction Manual