Nihon Bisoh Co.,Ltd. BISOMAC210 3Phase MM2014/11
KH-2014008 Rev.4
36
[CAUTION: Activation of BISOLOCK]
[Activation check of
BISOLOCK]
1. Insert wire rope to BISOLOCK approximately 12 inch.
2. Pull out wire rope quickly.
3. Confirm that BISOLOCK holds wire rope firmly.
4. Confirm that activation indicator lamp lights up when DOWN button is pressed.
5. Reset BISOLOCK by pulling down Release Lever. (Picture-9)
6. Confirm that activation indicator lamp does not light up when DOWN button is pressed.
NOTE:
If BISOLOCK is not activated and the platform continue falling, press Trip Button
to manually activate BISOLOCK.
CAUTION
1. Trip Button must be operated only by hand.
Trip Button may be broken and cause BISOLOCK unable to be activated normally.
2. DO NOT forcibly release BISOLOCK.
Safety pin inside Release Lever may be broken and cause BISOLOCK unable to be
deactivated.