INSTALLATION 

 

Step 1. Installing the Mounting Bracket 

 

 

Line up the holes of the light back cover plate D with the holes on your wall. Using 

 

  

            the two Drywall Screws C and fix it tightly in ide the wall using the 

Plastic Masonry Plug

 E.  

 

                          

 

 

 

 

           

WARNING: Risk of electric shock. Disconnect power at fuse or circuit breaker   

          before installing or servicing. 

 

 

             

CAUTION: Do not cut any wires with factory installed wire connectors or   

                               

remove the wire connectors.  

 

 

Step 2: Wiring the Light Fixture

 

 

 

Connect the light wires inside the connection block .The mains wire should pass through the 

Plastic Cover Bracket (D)  

 

Neutral (Blue) to Neutral (Blue)  

 

Earth (Green) to Earth ( Green/Yellow} 

 

Live ( Brown) to Live (Brown )  

 

Note: Make sure the polarity is correct. 

       

 
 

Содержание NW16TSP

Страница 1: ... read these instructions carefully prior to installation and retain them for future reference Failure to follow any of these instructions could void product warranties 0345 900 6764 www nightwatcher co uk support centre NW16TSP ...

Страница 2: ... circuit breaker box before wiring fixture to the power supply Verify that the supply voltage is correct Connect fixture to a 240volt 50 60 Hz power source Make sure all electrical and grounded connections are in accordance with the National Electrical Code and any applicable local code requirements All wiring connections must be proper isolated between wire connectors CAUTION RISK OF PRODUCT DAMA...

Страница 3: ...s Install the motion sensor 6 5 ft 1 9 m 10 ft 3 m above the ground Motion sensor is less sensitive above 10 ft 3 m Mount motion sensor so motion moves across detection zone Mount sensor away from heat producing sources to prevent false triggering Also be very careful not to include objects such as windows white walls and water in the detection zone Mount fixture away from moving objects such as t...

Страница 4: ...G LIST Part Description Quantity A Screw Hole Silicon cover 1 B M4 X 56mm Center Screw 1 C Drywall screw 2 D Light Back Cover Plate 1 E Plastic Masonry Plug 2 User Manual 1 Mounting Hardware included Tools Required for Installation Not included ...

Страница 5: ...ic shock Disconnect power at fuse or circuit breaker before installing or servicing CAUTION Do not cut any wires with factory installed wire connectors or remove the wire connectors Step 2 Wiring the Light Fixture Connect the light wires inside the connection block The mains wire should pass through the Plastic Cover Bracket D Neutral Blue to Neutral Blue Earth Green to Earth Green Yellow Live Bro...

Страница 6: ...t Fixture screw hole with A the Decorative Silicon Cover Note Make sure all the wires are properly connected inside the connection block before attaching the light to the wall Step 4 Caulking Around the Light Fixture Caulking Around the Light Fixture For additional protection caulk around the joint between the light fixture and mounting bracket using a silicon sealant not included ...

Страница 7: ...ction Adjust the lamp head direction by moving up and down Note LED LAMPS ARE NON REPLACEABLE Do not attempt to access maintain the LEDs they are non replaceable and any contact may damage the LEDs and will void the warranty 2 The Motion Sensor Detector Detection Range 49 2 ft 15 M 220 degrees on an optimum installation height of 2 5 meters Note When you first install your security light ensure th...

Страница 8: ...15M Dusk Level Ambient Light LUX Setting This setting is used to control the ambient light level for the motion security light to turn on You can set the light to turn on only in the darkness by turning the LUX setting to counter clockwise position Or allow the security light to trigger even during daylight by turning the LUX setting to full clockwise or at ambient light level in between NB LED LA...

Страница 9: ...and with NOT be controlled by time duration or ambient light LUX levels The MANUAL MODE will change to AUTO MODE in 6 hours automatically During MANUAL MODE by switching the main switch OFF then back ON again the PIR sensor will reset the warm up period and then AUTO MODE SPECIFICATIONS 1 Detection Method Passive Infrared Sensor PIR 2 Sensor Range 2M 15M x 220 degree spread approx 3 Time Adjustmen...

Отзывы: