TM Series
Operating & Safety Instructions
USA – 05/11
Issue 01
20
4.3
GROUND CONTROL OPERATION
ALWAYS ALLOW THE ENGINE TO WARM UP BEFORE OPERATING.
4.3.1
GROUND CONTROL INSTRUCTIONS
ALL MODELS
1)
Check below, above and around the platform for any obstructions or hazards before operating
any function.
2)
Ensure all red emergency stops are out.
3)
Turn the key switch at the ground control station to the “ON” position (i.e. clockwise).
4)
Battery/Electric models go to step 11).
DIESEL ENGINE OR BI-ENERGY MODELS
5)
Turn the main engine ignition switch, located on the side of the canopy through “ON”, to the
“ST” (start) position and the engine will fire.
6)
Go to step 11). Note – Unless the diesel engine is running, the TM34T will automatically default
to the primary power source (usually battery)
GASOLINE ENGINE OR GASOLINE/ELECTRIC MODELS
7)
For a cold engine start go to step 8) or for a warm engine start go to step 9).
8)
COLD ENGINE:
- turn the engine fuel tap “ON” and engage the choke lever. Turn the main engine
ignition through “ON” to “ST” (Start) and the engine will fire. Return the choke lever to its
normal running position after the engine is started.
9)
WARM ENGINE:
- turn the engine fuel tap on and turn the main engine ignition through “ON” to
“ST” (start) position and the engine will fire.
10)
Go to step 11). Note – Unless the petrol engine is running, the TM34T will automatically default
to the primary power source (usually battery)
ALL MODELS
11)
Push and hold green power button.
12)
Select the boom function required and operate hand levers in full accordance with
manufacturers Operating and Safety manual.
13)
When not in use return machine to stowed position, fully raise and stow all outriggers, turn the
key to the “OFF” position (i.e. anti-clockwise), remove key and chock wheels.
EMERGENCY PROCEDURES
1)
Push in red emergency stop to shut down all functions.
2)
Use emergency hand pump to provide motive power and manoeuvre the machine as normal
using the hand levers (Basket or Base).