manualshive.com logo in svg
background image

Kestrel® 2500 Pocket Weather® Meter

5

are pressed while the backlight is illuminated, the backlight will remain illuminated for 

another 10 seconds. Press 

MAX

AVG

 while the backlight is illuminated to manually turn o

ff

 

the backlight. 

7.   

Adjust the clock

. Simultaneously press 

MAX

AVG

 and 

MAX

AVG

 to adjust the clock. While the clock is 

blinking, press 

MAX

AVG

 or 

MAX

AVG

 to adjust the clock. Hold 

MAX

AVG

 or 

MAX

AVG

 to adjust the times quickly. 

Simultaneously press 

MAX

AVG

 and 

MAX

AVG

 to exit the clock adjustment.

8.   

Turn o

ff

. Hold 

MAX

AVG

 for 2 seconds to manually turn o

ff

 the unit. The unit will automatically 

turn o

ff

 if no buttons have been pressed for 45 minutes.

UNDERSTANDING THE MEASUREMENTS 

Wind Speed

 - average over the previous three seconds. The measurement will be accurate 

for air 

fl

ow through the front or rear of the unit.

Maximum Wind Gust

 - maximum 3 - second wind speed since the unit was turned on.

Average Wind Speed

 - average wind speed since the unit was turned on.

Temperature

 - instantaneous temperature of the thermistor, which is located at the end 

of the long coiled leads in the open cavity below the impeller. The exposed thermistor will 

respond quickly to changes in temperature when air 

fl

ows past it. For fastest response, either 

hold the unit into the wind or wave the unit side to side for 15 seconds. Readings should be 

taken in the shade. Water and snow temperatures can be taken by hold the unit in the water 

or snow.

Wind Chill

 - combination of wind speed and temperature, as de

fi

ned by the US National 

Weather Service. Wind chill is the e

ff

ective temperature on a human or animal at low 

temperatures due to wind speed. Wind chill readings will be the same as the temperature 

readings above 45ºF or below 3 mph.

Altitude and Barometric Pressure

 - the Kestrel 2500 will measure station pressure in order 

to calculate barometric pressure and altitude. Changes in either air pressure or altitude will 

a

ff

ect these readings, so it’s important to make adjustments as necessary.

ABOUT BAROMETRIC PRESSURE AND ALTITUDE ADJUSTMENTS

The Kestrel Meter measures “station” pressure, the actual air pressure in the measurement 

location, and uses this value to calculate barometric pressure and altitude. Station pressure 

changes in response to two things—changes in altitude and changes in the atmosphere. 

Because the Kestrel Meter is constantly changing location and altitude, it is important to 

enter adjustments or “references” when accurate pressure and altitude readings are needed.
Barometric pressure is station pressure corrected to sea level. In order to make the 

correction, the Kestrel Meter needs an accurate reference altitude. Altitude is the height 

above sea level. In order to correctly calculate altitude, the unit needs an accurate barometric 

pressure reference, also known as an “altimeter setting”. Fortunately, you only need to know 

ONE of these values (current barometric pressure or current altitude) in order to set your 

Kestrel Meter up to show accurate readings. 

Starting with the known barometric pressure for your location

[email protected]

1.800.561.8187

www.

.com

Содержание Kestler 2500

Страница 1: ...ll maximum wind gust barometric pressure average wind speed altitude temperature air water snow 2500 Pocket Weather Meter with Backlight Revised 07 28 10 INSTRUCTION MANUAL Plus additional features wa...

Страница 2: ...F Wind Chill chill C F Mode Hint Icon Units of Measure Barometric Pressure hPa inHg Altitude Alt m ft Only one of the pressure icons will be displayed indicating the 3 hour pressure trend pressure ris...

Страница 3: ...Wind Chill combination of wind speed and temperature as defined by the US National Weather Service Wind chill is the effective temperature on a human or animal at low temperatures due to wind speed Wi...

Страница 4: ...ange with changes in the reference altitude Simultaneously press MAX AVG and M A X A V G to exit the reference altitude adjustment Again allow the Kestrel Meter to stabilize then enter the value from...

Страница 5: ...ailable where watch batteries are sold Wipe the battery clean of any fingerprints and insert the positive pole up angling the battery downward and pressing it firmly into place When replacing the batt...

Страница 6: ...system for estimating wind force without the use of instruments based on the visible effects of the wind on the physical environment The behavior of smoke waves trees etc is rated on a 13 point scale...

Страница 7: ...exclusive remedy with respect to any breach of the NK Limited Warranty set forth herein All product liability and warranty options are governed exclusively by the laws of the Commonwealth of Pennsylva...

Страница 8: ...accordance with N I S T requirements and based on a regular schedule Only approved laboratories and N I S T themselves are used for these calibration services Incoming and outgoing data is supplied wi...

Страница 9: ...ERMAN 21 Creek Circle Boothwyn PA 19061 Phone 610 447 1555 Fax 610 447 1577 Web www kestrelweather com Email kestrel nkhome com Register your Kestrel Pocket Weather Meter online at www kestrelweather...

Отзывы: